background image

©Copyright Task Force Tips LLC 2022

4

LIC-020 May 5, 2022 Rev00

3.0 INSTALLATION

3.1 CARTRIDGE INSTALLATION

The cartridge is shipped in the unit with a protective wrap covering. Prior to starting the unit, remove the protective wrap and reinstall the

cartridge following the instructions in "Changing the cartridge" on page 7. 

3.2 MOUNTING

1. Choose a mounting location.

2. To ensure proper hole location, use the mounting bracket as a template.

A. Remove (2) screws from the right and left sides of the unit to separate the mounting bracket from the unit.

3. Secure the bracket using (4) nuts and bolts (not provided).

4. Secure the unit to the bracket by replacing the screws removed in step 2A.

Figure 3.2

NOTICE

Protective plastic wrap should not be removed from the cartridges until ready for installation as the 

effectiveness of the molecular material starts degrading after exposure to oxygen.

Failure to remove the protective wrap from the cartridge prior to installation will cause the unit to 

overheat and turn off due to lack of air flow.  

WARNING

An inadequately secured unit may become dislodged as a result of a sudden stop or collision, 

causing injury or equipment damage. To reduce the risk of injury:

• Mount the device on a surface material capable of supporting 50 pounds in the direction of truck

travel and 15 pounds in any other direction, per NFPA 1901.

• Use fasteners of a size, strength, and length adequate to securely hold the device. 

NOTICE

To ensure proper air flow and function of the CrewProtect:

• Choose a location where there is at least 1” of free space around all air ducts.

• Keep air ducts free from obstruction by loose items such as clothing, paper, dirt, or equipment.

• Do not place heavy objects on the unit.

• Do not use the unit as a shelf. 

7.3 (185)

6.1 (155)

3.0 (76)

5.44 (138)

4X R.100
      (2.5)

MOUNTING BRACKET   

HOLE PLACEMENT

COMPLETE UNIT     

OVERALL DIMENSIONS

Содержание CrewProtect 20

Страница 1: ...Air Decontamination System DANGER Understand manual before use Operation of this device without understanding the manual and receiving proper training is a misuse of this equipment Obtain safety information at tft com serial number This instruction manual is intended to familiarize installers end users and maintenance personnel with the operation servicing and safety procedures associated with thi...

Страница 2: ... RESPONSIBILITY to read and understand any user s instructions including purpose and limitations provided with any piece of equipment you may be called on to use 3 IT IS YOUR RESPONSIBILITY to know that you have been properly trained in Firefighting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 IT IS YOUR RESPONSIBILITY to be in prope...

Страница 3: ...ECIFICATIONS Table 2 2 DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practic...

Страница 4: ...cular material starts degrading after exposure to oxygen Failure to remove the protective wrap from the cartridge prior to installation will cause the unit to overheat and turn off due to lack of air flow WARNING An inadequately secured unit may become dislodged as a result of a sudden stop or collision causing injury or equipment damage To reduce the risk of injury Mount the device on a surface m...

Страница 5: ...y to the truck electrical system continuous air decontamination occurs the entire time the truck is actively powered Regular cartridge replacement ensures optimal air decontamination See section 6 0 on page 7 for cartridge lifecycle and replacement instructions NOTICE Always disconnect power before installing or servicing electrical components Failure to do so could cause damage to the circuit boa...

Страница 6: ...f its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequentia...

Страница 7: ...e Hours of Continuous Use or Months of Intermittent Use LED Color 0 1500 0 4 9 Solid Blue 1501 1799 5 5 9 Solid Yellow 1800 6 Solid Red NOTICE To ensure the device is optimally decontaminating the cabin air the cartridge should be changed when the LED color is YELLOW When the indicator turns RED the device will stop operating until the cartridge is replaced with a new cartridge NOTICE All replacem...

Страница 8: ...N SERVICE the CrewProtect 20 must be inspected to this checklist 1 There is no obvious damage such as missing broken or loose parts damaged labels etc 2 The unit is securely fastened to the truck 3 LED status lights indicating cartridge status are in the acceptable range Blue or Yellow 4 All air ducts are clean and unobstructed 5 The area around the device is clean and free of loose debris 6 There...