6 – Modules
ST IN 1–2 MODULE (OVERVIEW) Screens
ST IN 1–2 module when the input source is ANALOG
1
Metering Point button
o
This shows the name of the set metering point.
o
Tap this button to open a window for setting metering
points for ST IN 1–2 modules.
Options: INPUT, PRE EQ (default), PRE FADER,
POST FADER
Tap an option to switch the metering point for the level
meter.
NOTE
Metering points can also be changed on the METERING
POINT page of the METER SETUP Screen. (See “METERING
2
Level meters
This shows the level of the signal at the set metering point.
3
MUTE GROUP button
Tap this button to open the DCA/Mute Group SETUP Screen
Mute Group Assign page. (See “Mute Group Assign page” on
4
DCA button
Tap this button to open the DCA/Mute Group SETUP Screen
DCA Assign page. (See “DCA Assign page” on page 120.)
5
MUTE GROUP 1–8 buttons
Tap these buttons to change Mute Group assignment states.
(Default: off)
Assigned buttons will be highlighted.
6
DCA 1–8 buttons
Tap these buttons to change DCA assignment states.
(Default: off)
Assigned buttons will be highlighted.
7
Snapshot Recall Safe button
Tap this button to enable the Snapshot Recall Safe function
for the selected module. (Default: off)
When this is on, the button will appear highlighted.
NOTE
This can also be set on the MODULE SAFE page of the
SNAPSHOT RECALL SAFE Screen. (See “MODULE SAFE page”
8
Metering Point position indicator
The highlighted indicator shows the position of the set
metering point.
9
INPUT button
o
This shows the input source name.
o
Tap this button to open the INPUT SOURCE SELECT
Screen. (See “INPUT SOURCE SELECT screen” on page
0
+48V button
o
This shows the +48V button when the input source of the
selected module is “ANALOG” or “SB-16D connected by
built-in Dante”.
o
Touch and hold the +48V button to turn phantom power
(+48V) on/off. (Default: off)
When phantom power is on, the button will be
highlighted.
q
PAD button
o
This shows the PAD button when the input source of the
selected module is “ANALOG” or “SB-16D connected by
built-in Dante”.
o
Tap this button to turn the –20dB pad on/off. (Default: off)
When this button is on, it will appear highlighted.
NOTE
When the pad is switched on/off, the Analog GAIN value will
be controlled as shown below so that it changes as little as
possible.
When Analog Reference Level = +6 dBu
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +3 – +37
Same value
PAD ON/Analog GAIN: −17 – +2
+3
PAD OFF/Analog GAIN: +38 – +57 +37
When Analog Reference Level = +4 dBu
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +12 – +46
Same value
PAD ON/Analog GAIN: −8 – +11
+12
PAD OFF/Analog GAIN: +47 – +66 +46
When Analog Reference Level = 0 dBu
Status before switching pad
setting
Analog GAIN after
switching pad setting
Analog GAIN: +8 – +42
Same value
PAD ON/Analog GAIN: −12 – +7
+8
PAD OFF/Analog GAIN: +43 – +62 +42
82
TASCAM Sonicview 16/Sonicview 24