Tascam MMR-16 Скачать руководство пользователя страница 5

TASCAM MMR-8/MMP-16 Version 4.6 Owner’s Manual Update

- 4 -

Ability to work with "Wide-Narrow-Wide" SCSI setups

The MMR-8/MMP-16 now has the ability to work with a wide SCSI hard drive, enclosed in a
narrow SCSI carrier, that is in turn inserted into a wide SCSI receiving frame connected to the
internal wide SCSI card.

There are no special menu operations to allow this scenario. This combination of SCSI hardware
will now simply work reliably, whereas it would not with previous software versions.

Miscellaneous Pro Tools Enhancements

Version 4.6 improves upon several areas of Pro Tools compatibility:

Previously, users would have difficulty spotting MMR-8/MMP-16 generated SDII files into Pro
Tools 5.1. With version 4.6 software, the MMR-8/MMP-16's SDII files will now spot correctly into
Pro Tools 5.1.3. (Note: ProTools version 5.1 had spotting bugs that were fixed in ver. 5.1.3.)

Previously, users bringing Pro Tools projects over to an MMR-8/MMP-16 would occasionally
experience a loss of audio at the very beginning and ending of individual regions. This has now been
corrected with version 4.6

Miscellaneous Enhancements

  Renaming tracks:

Previously, renaming of tracks caused unexpected behavior where a new project would be created
with the new name containing the track that was selected with the same name. Track renaming has
never actually been permitted on the MMR/MMP’s. Now an attempt to rename a track will result
in an error message that track renaming is not allowed.

 Sync-II Idle On error:

With version 4.5, some users of older hardware would experience a "Sync-II Idle On" error when
loading the 4.5 software. This has been corrected and will not occur when loading version 4.6

  Wide SCSI card operation:

Previously, machines with a wide SCSI card installed could exhibit sluggish transport and chase lock
behavior when chasing SMPTE Time Code or another MMR-8/MMP-16. This has been corrected
in version 4.6.

  SoundMaster Compatibility:

Previously there were transport control and synchronization issues when using a SoundMaster
system to control the MMR-8 and MMP-16.  These issues have been resolved in version 4.6.  This
update applies to M-2 UNITS ONLY.

Содержание MMR-16

Страница 1: ...73248 TASCAM TEAC Professional Division MMR 8 Modular Multitrack Recorder MMP 16 Modular Multitrack Player MMR 8 MMP 16 Version 4 6 OWNER S MANUAL UPDATE...

Страница 2: ...REHEARSE AUTO PUNCH FEATURE ON M2 MMR 8S 3 ABILITY TO WORK WITH WIDE NARROW WIDE SCSI SETUPS 4 MISCELLANEOUS PRO TOOLS ENHANCEMENTS 4 MISCELLANEOUS ENHANCEMENTS 4 Renaming tracks 4 Sync II Idle On er...

Страница 3: ...ftware is being copied from the floppy disk to the system s internal disk drive After a few moments the machine will prompt Insert Disk 2 Remove the 1st disk and insert the second floppy Press STO Aft...

Страница 4: ...these formats NOTE When switching between using an HFS and HFS formatted drive on the MMR 8 MMP 16 the machine must be fully rebooted The machine must also be rebooted when switching from an HFS to a...

Страница 5: ...loss of audio at the very beginning and ending of individual regions This has now been corrected with version 4 6 Miscellaneous Enhancements Renaming tracks Previously renaming of tracks caused unexp...

Страница 6: ...hines This has been corrected with version 4 6 Special Alpha character support Previously users would experience difficulty mounting disks containing Pro Tools projects that utilized special alpha cha...

Страница 7: ...a project a project folder with the same name as the session is automatically created and is placed inside the MMR 8 projects folder that is also automatically created when the disk is mounted If the...

Страница 8: ...58 1943 TEAC UK LIMITED 5 Marlin House Marlins Meadow The Croxley Centre Watford Herts WD1 8YA U K Phone 01923 819699 TEAC DEUTSCHLAND GmbH Bahnstrasse 12 65205 Wiesbaden Erbenheim Germany Phone 0611...

Отзывы: