Tascam LA-40MKIII Скачать руководство пользователя страница 3

TASCAM LA-40MKIII 

3

 

1

  Read these instructions.

 

2

  Keep these instructions.

 

3

  Heed all warnings.

 

4

  Follow all instructions.

 

5

  Do not use this apparatus near water.

 

6

  Clean only with dry cloth.

 

7

  Do  not  block  any  ventilation  openings.  Install  in 

accordance with the manufacturer's instructions.

 

8

  Do  not  install  near  any  heat  sources  such  as 

radiators,  heat  registers,  stoves,  or  other  apparatus 
(including amplifiers) that produce heat.

 

9

  Do  not  defeat  the  safety  purpose  of  the  polarized 

or  grounding-type  plug.  A  polarized  plug  has  two 
blades  with  one  wider  than  the  other.  A  grounding 
type  plug  has  two  blades  and  a  third  grounding 
prong.  The  wide  blade  or  the  third  prong  are 
provided  for  your  safety.  If  the  provided  plug  does 
not  fit  into  your  outlet,  consult  an  electrician  for 
replacement of the obsolete outlet.

 

10

  Protect  the  power  cord  from  being  walked  on 

or  pinched  par ticularly  at  plugs,  convenience 
receptacles,  and  the  point  where  they  exit  from  the 
apparatus.

 

11

  Only  use  attachments/accessories  specified  by  the 

manufacturer.

 

12

  Use  only  with  the  cart,  stand,  tripod,  bracket,  or 

table specified by the manufacturer, or sold with the 
apparatus.  When  a  cart  is  used,  use  caution  when 
moving  the  cart/apparatus  combination  to  avoid 
injury from tip-over.

 

13

  Unplug  this  apparatus  during  lightning  storms  or 

when unused for long periods of time.

 

14

  Refer  all  servicing  to  qualified  service  personnel. 

Servicing  is  required  when  the  apparatus  has  been 
damaged in any way, such as power-supply cord or 
plug  is  damaged,  liquid  has  been  spilled  or  objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

Do not expose this apparatus to drips or splashes.

• 

Do  not  place  any  objects  filled  with  liquids,  such  as 

• 

vases, on the apparatus.
Do not install this apparatus in a confined space such 

• 

as a book case or similar unit.
The  apparatus  draws  nominal  non-operating  power 

• 

from  the  AC  outlet  with  its  POWER  or  STANDBY/ON 
switch not in the ON position.
The apparatus should be located close enough to the 

• 

AC outlet so that you can easily grasp the power cord 
plug at any time. 
The  main  plug  is  used  as  the  disconnect  device,  the 

• 

disconnect device shall remain readily operable.
An  apparatus  with  Class  I  construction  shall  be 

• 

connected to an AC outlet with a protective grounding 
connection.
Batteries (battery pack or batteries installed) shall not 

• 

be exposed to excessive heat such as sunshine, fire or 
the like.
Excessive  sound  pressure  from  earphones  and  head-

• 

phones can cause hearing loss.

IMPORTANT SAFETY INSTRUCTIONS

E_LA-40mkIII-OM_RevC.indd   3

08.12.19   1:03:23 PM

Содержание LA-40MKIII

Страница 1: ...D01047720C LA 40 Balanced Unbalanced Line Converter OWNER S MANUAL E_LA 40mkIII OM_RevC indd 1 08 12 19 1 03 23 PM...

Страница 2: ...voquer des interf rences radio dans ce cas l utilisateur peut tre amen prendre des mesures appropri es F r Kunden in Europa Warnung Dies ist eine Einrichtung welche die Funk Entst rung nach Klasse A b...

Страница 3: ...ion to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required w...

Страница 4: ...ing the unit 5 2 Names and Functions of Parts 6 Front panel 6 Rear panel 6 Bottom panel 7 Block diagram 8 Level diagram 9 3 ADA Functions 10 Example 1 10 Example 2 10 Example 3 11 Example 4 11 4 Speci...

Страница 5: ...s Three prong AC power outlet Not on EUR model Overview Supplied accessories The following items are included with this product Main unit 1 Power cord set 1 Rack mount screw set 1 Owner s Manual this...

Страница 6: ...ere multiple units are connected a ground loop can occur through the wiring and this loop can cause a hum or other noise If this occurs engage GND LIFT switches to cut ground loops from the balanced O...

Страница 7: ...an also be assigned to multiple outputs in sequence see 3 ADA Functions for examples o INPUT LINK switches 6 8 These switches allow an input signal to be routed to any higher numbered output from 6 8...

Страница 8: ...8 TASCAM LA 40MKIII 2 Names and Functions of Parts Block diagram UNBALANCED TO BALANCED BALANCED TO UNBALANCED E_LA 40mkIII OM_RevC indd 8 08 12 19 1 03 24 PM...

Страница 9: ...TASCAM LA 40MKIII 9 2 Names and Functions of Parts Level diagram UNBALANCED TO BALANCED BALANCED TO UNBALANCED E_LA 40mkIII OM_RevC indd 9 08 12 19 1 03 24 PM...

Страница 10: ...annel 5 is output through balanced OUTPUTS 5 8 7 In this example a stereo pair of signals input through channels 5 and 7 are output in parallel to 2 channels each 1 Connect the left stereo signal to t...

Страница 11: ...stereo pair of signals input through channels 1 and 3 are output in parallel to 2 channels each 1 Connect the left stereo signal to the balanced INPUT 1 8 and the right stereo signal to the balanced...

Страница 12: ...k when all INPUT LINK switches are ON Nominal input level 4 dBu 1 dB INPUT LEVEL switch set to 4 dB 20 dBu 1 dB INPUT LEVEL switch set to 20 dB Maximum input level 30 dBu INPUT LEVEL switch set to 4 d...

Страница 13: ...ecifications Dimensional drawings NOTE In order to improve these units their specifications and external appearance may be changed without notification Please be aware that as a result of product impr...

Страница 14: ...14 TASCAM LA 40MKIII Memo E_LA 40mkIII OM_RevC indd 14 08 12 19 1 03 24 PM...

Страница 15: ...TASCAM LA 40MKIII 15 Memo E_LA 40mkIII OM_RevC indd 15 08 12 19 1 03 24 PM...

Страница 16: ...sauga Ontario L4Z 1Z8 Canada TEAC MEXICO S A de C V www teacmexico net Phone 52 55 5010 6000 R o Churubusco 364 Colonia Del Carmen Delegaci n Coyoac n CP 04100 M xico DF M xico TEAC UK LIMITED www tas...

Отзывы: