background image

11

 

The canopy is not designed to carry snow loads. In the event there is snow on the 
canopy panels or the panels are covered in ice, please remove the snow and/ or 
ice layer immediately. 
 
In order to maintain the water drainage system unobstructed, it is necessary to 
check and remove waste such as leaves, conifer needles, and other type of waste 
from the gutters at least twice a year. This shall help maintain the flow capacity 
of the gutters mounted in the supporting legs of the structure. The manufacturer 
recommends that structures installed in the vicinity of natural environment shall 
be cleaned as often as it may be required.

 

 
It is recommended to check the state of the structure - in springtime, before the 
start of the summer season, and in the fall - before the canopy is closed for the 
winter  season.  The  structure  may  be  checked  more  often  if  alarming  events 
occur.  Defects  resulting  from  failure  to  comply  with  the  above  shall  not  be 
covered by the manufacturer's warranty. 
 
Due to the design of the structure, the guide rails and the canopy profiles shall be 
checked for the presence of ice before opening/ closing the canopy, particularly 
during  cold  temperatures.  Icing  may  damage  the  components  of  the  guides 
themselves as well as the electrical components and this shall not be covered by 
the  manufacturer's  warranty.  It  is  recommended  to  check  the  flow  capacity 
of  the guides each time before switching the  canopy  on (in case any foreign 
matter, such as leaves, sticks, insects or animals got inside) 

 ICING

 

Due to temperature differences, dew may appear on profiles and on the fabric, 
as well as condensation of water vapor under the canopy may occur 

 this shall 

not be deemed a product defect. 
Waste  causing  mechanical  damage  to  the  fabric  or  the  structure  shall  be 
removed before the roof is folded. 

 

While the canopy is being folded, residual rainwater may pour out from the fabric 
panels. 

 

Shade differences between aluminum elements coming in in different batches 
of the product may occur. 

 

Taking into consideration the high level of pollution which leads to acid rain, and 
in case the structure is installed near roads, air channels, forests, trees with a risk 
of  resin  contamination,  and  additionally  it  is  not  cleaned  immediately  after 
contamination,  then  the  profiles  may  get  dirty,  making  it  impossible  to  clean 
them later. 

Содержание Flat

Страница 1: ...1 Tarasola Flat TARASOLA CANOPY AND COMPONENTS USE AND MAINTENANCE MANUAL...

Страница 2: ...ICATION 3 3 TECHNICAL SPECIFICATION 3 3 1 Structure 3 3 2 Wind class 6 3 3 Electrical components for Tarasola Flat 6 3 4 Fabric components in the canopy 8 3 5 Technical limitations of the fabrics 9 4...

Страница 3: ...49 km h which corresponds to 6 in the Beaufort scale The calculations concerning wind load resistance were performed according to the standard PN EN 1932 2013 09 EXTERNAL BLINDS AND SHUTTERS RESISTAN...

Страница 4: ...brackets intended for screwing to the base 4 Side package an aluminum filling panel assembled together with a system gutter which collects and drains water as well as stiffens the structure 5 System...

Страница 5: ...5 Fig 1 Graphical representation of the freestanding Tarasola Flat Fig 2 Graphical representation of the Tarasola Flat wall structure...

Страница 6: ...roducts we are offering a comprehensive product to our Clients the best on the market WARNING Due to the complexity and specificity of the product installation shall be performed by qualified personne...

Страница 7: ...s having a switchboard Warning All wiring connection diagrams shall be obeyed otherwise warranty may be voided REMOTE CONTROLLER Manual radio control of one or more RTS drives and or radio receivers o...

Страница 8: ...LURE TO THE MANUFACTURER ONLY QUALIFIED PERSONNEL SHALL ENGAGE IN REPAIRING THE ELECTRICAL SYSTEM ANY ACTIONS CONSTITUTING SELF REPAIR AND NEGATIVE EFFECTS OF SUCH ACTIONS MAY RESULT IN THE WARRANTY B...

Страница 9: ...ls creates a protective layer against dirt water and oily substances During rainfall water drops run down easily when the canopy is sloped Weather and mechanical conditions gradually reduce the effect...

Страница 10: ...r s consent This increases the risk of product failure and shall result in the product warranty being voided Be careful when opening and closing the canopy Due to the risk of damaging one s hands it i...

Страница 11: ...checked for the presence of ice before opening closing the canopy particularly during cold temperatures Icing may damage the components of the guides themselves as well as the electrical components a...

Страница 12: ...canopy during conditions exceeding the indicated wind standard may result in damage or destruction of the canopy It is forbidden to place any items or objects on the material of the structure The arr...

Страница 13: ...13 5 CERTIFICATES...

Отзывы: