The canopy is not designed to carry snow loads. In the event there is snow on the
canopy panels or the panels are covered in ice, please remove the snow and/ or
ice layer immediately.
In order to maintain the water drainage system unobstructed, it is necessary to
check and remove waste such as leaves, conifer needles, and other type of waste
from the gutters at least twice a year. This shall help maintain the flow capacity
of the gutters mounted in the supporting legs of the structure. The manufacturer
recommends that structures installed in the vicinity of natural environment shall
be cleaned as often as it may be required.
It is recommended to check the state of the structure - in springtime, before the
start of the summer season, and in the fall - before the canopy is closed for the
winter season. The structure may be checked more often if alarming events
occur. Defects resulting from failure to comply with the above shall not be
covered by the manufacturer's warranty.
Due to the design of the structure, the guide rails and the canopy profiles shall be
checked for the presence of ice before opening/ closing the canopy, particularly
during cold temperatures. Icing may damage the components of the guides
themselves as well as the electrical components and this shall not be covered by
the manufacturer's warranty. It is recommended to check the flow capacity
of the guides each time before switching the canopy on (in case any foreign
matter, such as leaves, sticks, insects or animals got inside)
–
ICING
.
Due to temperature differences, dew may appear on profiles and on the fabric,
as well as condensation of water vapor under the canopy may occur
–
this shall
not be deemed a product defect.
Waste causing mechanical damage to the fabric or the structure shall be
removed before the roof is folded.
While the canopy is being folded, residual rainwater may pour out from the fabric
panels.
Shade differences between aluminum elements coming in in different batches
of the product may occur.
Taking into consideration the high level of pollution which leads to acid rain, and
in case the structure is installed near roads, air channels, forests, trees with a risk
of resin contamination, and additionally it is not cleaned immediately after
contamination, then the profiles may get dirty, making it impossible to clean
them later.