CAUTION: All connections to power supply, input and output connectors must be
carried out only with amplifier off.
Installation
Output cables wire gauge*_____________________________
______________ 9 AWG
Caution: Using wire gauges less than recommended may result in power loss and wires
overheating .
Protection fuse or circuit breaker
_______________________________________ 150A
*Wire gauge calculated considering a 4m maximum length. For longer distance
increase the cable gauges.
Check polarity and never reverse power supply cables due to the risk of amplifier
damage.
It is compulsory to install a protection fuses or circuit breakers as close as possible from
batteries.
Remote cable ___________________
_________________________________ 18 AWG
Positive / negative power supply cable *______________
__Min. 4 AWG / Max.1/0 AWG
Note: Required battery bank capacity:
At least 150Ah
Recommended wire gauge & fuse
Note:
In case of compression driver you must
install a passive filter in the positive terminal
of the same ones (Consult transducer’s
manufacturer manual).
11
SPEAKER
IN
OUT
MONITOR
0.2
GAIN
4
BASS BOOST
BOOST
+10
0
dB
FREQ.
55
35
Hz
Hz
Hz
LOW PASS
90
10
CROSSOVER
HIGH PASS
10K
90
V
Illustrative images
Remote Cable 0,75mm² / 18 AWG
DISJUNTOR
50mm² (1/0 A
WG)
6mm² (9 AWG)
50mm² (1/0 A
WG)
6mm² (9 AWG)
Head Unit
Other Amplifier
IN
OUT
RCA Cables
Taramps
GND
12V
ENGLISH
Содержание SMART 3
Страница 1: ......
Страница 14: ...MN_010506_R00...