Remote Cable 18 A
WG
CIRCUIT BREAKER
CIRCUIT BREAKER
12V
GND
2 x 70mm²
2 x 70mm²
10mm² (7 AWG)
10mm² (7 AWG)
Second
Amplifier
R
C
A Cable
Taramps
llustrative images
Head Unit
11
Positive / negative power supply cable ___________________
_______________2 x 2/0 AWG
Output cables wire gauge_______________________________
_________________7 AWG
Remote cable ___________________
______________________________________ 18 AWG
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Protection fuse or circuit breaker
___________________________________________1160A
Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
CAUTION
This equipment is not suitable
for use in places where children may be present.
CAUTION
Examples of connections in the power supply input.
Note: Required battery bank capacity: At least 1160Ah
The entire aluminum
surface of the amplifier
serves as a heat sink. The usually working
temperature is 65°C. So, avoid contact with
this surface when the amplifier is in use.
CAUTION