Amplifier
2
CIRCUIT BREAKER
CIRCUIT BREAKER
12V
GND
Head Unit
R
C
A Cable
Taramps
2 x 70mm²
2 x 70mm²
10mm² (7 AWG)
10mm² (7 AWG)
llustrative images
Remote Cable 18 A
WG
11
Remote cable ___________________
______________________________________ 18 AWG
Positive / negative power supply cable ___________________
_______________2 x 2/0 AWG
Output cables wire gauge_______________________________
_________________7 AWG
Protection fuse or circuit breaker
____________________________________________650A
Calculated considering a maximum length of 4m. Distance greater than this, you will need to
increase the cable gauges.
Installation
Recommended wire gauge & fuse
CAUTION: All connections to power supply, input and output connectors must
be carried out only with amplifier off.
CAUTION
It is compulsory to install a protection fuses or circuit breakers as close as possible from batteries.
Check polarity and never reverse power supply cables due to the risk of damage to the amplifier.
Using wire gauges below the recommendation will result in power loss and
overheating of wiring.
CAUTION
This equipment is not suitable
for use in places where children may be present.
CAUTION
Examples of connections in the power supply input.
Note: Required battery bank capacity: At least 650Ah
The entire aluminum
surface of the amplifier
serves as a heat sink. The usually working
temperature is 65°C. So, avoid contact with
this surface when the amplifier is in use.
CAUTION