20
Please Remember
–
Only use tablet or pellet salt in your softener!
User information
(cont)
POWER CUTS
If the electrical power to the water softener is interrupted, the time display
will be blank, but the ‘memory’ built into the electronics will keep the
correct time for up to 48 hours.
The water softener will not recharge but will pass softened water.
In the case of a power cut, your demand for water will be less as most
appliances will not work, so a recharge should not be necessary. When
electrical power is returned, one of two things will happen:
1. Power off up to 48 hours
The display returns and is steady, no operation is necessary.
2. Power off over 48 hours
The display returns and flashes, only the time requires re-setting.
The hardness and recharge time will not have been lost as they are
stored. Even if the time is incorrect, the water softener will continue to
work but will recharge at what it believes the time to be. Re-set the time
as described in the programming section (see page 11 for AD11/AD15
and page 14 for Ultra 9).
SHOULD AN ERROR CODE
APPEAR
Check electrical connections are
as per configuration on page 9
• Unplug transformer
• Check direct connections
• Replug transformer
• Wait for 6 minutes, if the error is
rectified, the error code will not appear.
The softener may recharge immediately following a cleared error code.
ERRO1
Содержание AD11
Страница 27: ......