10 

PRSU/4, PRSU/5 Operating Instructions Manual (Revision 3.0) 

Technical Data 

 

Electrical data

 

 

 
 
Supply Voltage U

V

 

PRSU/4 

24V

DC 

Or 24V

AC 

 
PRSU/5 

115V

AC

 

Voltage Range 

U

± 10% 

U

± 10% 

Frequency  

48Hz (min) to 62Hz (max) 

48Hz (min) to 62Hz (max) 

Power Consumption (typ.) 

+24V

DC

: 3W, 24V

AC

: 5VA 

5VA 

 

 

 

4-Wire Safety Switches

 

 

Maximum Short Circuit Resistance 

<= 200 

 

<= 200 

 

Maximum Signal Wires Resistance 

<= 10 

 

<= 10 

 

 

 

 

Conductor Data 

 

Conductor Connection 

2 x 1.5 mm

2

  solid wire 

2 x 1.5 mm

2

  stranded wire-end ferrule  

  

UL: Use 60/75°C copper wire only! 

2 x 1.5 mm

2

  solid wire 

2 x 1.5 mm

2

  stranded wire-end ferrule 

 

UL: Use 60/75°C copper wire only! 

Max. Conductor Length (input circuit) 

2 x 100m (Single channel) 
4 x 100m (Dual channel) 

2 x 100m (Single channel) 
4 x 100m (Dual channel) 

Conductor Cross-Section 

1.5 mm

 

1.5 mm

2

 

Capacitance/cable length 

150 nF/km (maximum) 

150 nF/km (maximum) 

Reference Temperature 

+ 25°C 

+ 25°C 

 

 

 

Contact Data

 

 

Contact Allocation 

3 N.O. safety, 1 N.C. aux 

3 N.O. safety, 1 N.C. aux 

Contact Type 

Relay positive guided 

Relay positive guided 

Contact Material 

AgSnO

2

 or comparable material 

AgSnO

2

 or comparable material 

Switching Voltage 

240V

AC

, 24V

DC

 

240V

AC

, 24V

DC

 

Max. Switch/Relay Current 

5A (individual), 3.8A (combined) 

5A (individual), 3.8A (combined) 

Min. Switching Current 

10mA 

10mA 

Max. Switching Capability (per relay) 
DIN EN 60947-5-1 

AC 15  230 V / 5 A 
DC 13    24 V / 5 A 

AC 15  230 V / 5 A 
DC 13    24 V / 5 A 

Max. Switching Capacity 

1200 VA (resistive load) 

1200 VA (resistive load) 

Mechanical Lifetime 

10

7

 switching cycles 

10

7

 switching cycles 

Electrical Lifetime 

10

5

 switching cycles  (DC 24V/2A) 

10

5

 switching cycles  (DC 24V/2A) 

Creeping Distance and                                      
Clearance                                                                                                     

-EN 50178 at pollution grade 2, over voltage 
category 3 /250V 
-Basis isolation: over voltage  
category 3 / 250 V 

-EN 50178 at pollution grade 2, over voltage 
category 3 /250V 
-Basis isolation: over voltage  
category 3 / 250 V 

Contact Security 

NO contact: 6.3A brief 
NC contact: 4A gL/gG 

NO contact: 6.3A brief 
NC contact: 4A gL/gG 

Short Circuit Withstand 
(IEC60947-5-1) 
Weld Free Protection at I

PSCC

≥1kA SCPD  

(Short Circuit Protection Device)  
(Fuse links), size D01  
acc IEC IEC60269-1; IEC60269-3-1; VDE036-
T301 

NO-contacts:  

6A 

NC-contacts: 

6A 

 
 
 

 

NO-contacts:  

6A 

NC-contacts: 

6A 

 

Restarting Readiness Time (minimum switch off 
time the inputs) 

0.5 s 

 
0.5 s 

Delay on De-energisation  

<  30 ms, 24V AC: < 50ms 

<  30 ms 

 

 

 

Mechanical Data

 

 

Housing Material 

Polyamide PA 6.6 

Polyamide PA 6.6 

Dimensions (W 

D) 

22.5mm x 114.5mm x 99mm 

22.5mm x 114.5mm x 99mm 

Fastening 

Click-fastening for DIN-Rail 

Click-fastening for DIN-Rail 

Humidity 

95% 0-50°C  

95% 0-50°C 

Torque Setting for Connection Terminals  

0.5 Nm (min), 0.6 Nm (max) 

UL:  Overtorquing may cause  
enclosure breakage

 

         0.5 Nm (min), 0.6 Nm (max) 

         UL:  Overtorquing may cause  

enclosure breakage

 

Weight with Terminals 

Max. 180g 

Max. 180g 

Storage 

In dry areas 

In dry areas 

 

 

 

Environmental data

 

 

Operating Temperature 

-

25°C ... +55°C ( UL:…+40°C) 

-

25°C ... +55°C ( UL:…+40°C) 

Terminal Type 

IP 20 

IP 20 

Housing Type 

IP 40    

IP 40    

Shock Resistance of N.O./N.C. Contacts 

8/2g 

8/2g 

 

 

Certifications

 

 

Tested I.A.W. 

EN ISO 13849-1 

EN ISO 13849-1 

Achieved Level/Category 

Performance Level e, Cat. 3 

Performance Level e, Cat. 3 

DC 

90% (Medium - redundant switch off channel 
with monitoring) 

90% (Medium - redundant switch off channel 
with monitoring) 

CCF 

Achieved 

Achieved 

MTTF

 

100 years 

– high 

 

100 years 

– high 

PFH 

5,81 * 10

-9  

1/h 

5,81 * 10

-9  

1/h 

SFF

 

99%

 

99%

 

 
 

 

 

 

 

 

Содержание PRSU/4

Страница 1: ...plants who are familiar with the safety instructions and safety regulations Skilled personnel who build install maintain and operate safety equipment in plants and machinery Symbol Key These operating...

Страница 2: ...egulations for safety at work and accident prevention and who have read this manual s content in full Installation assembly and maintenance of electrical equipment is only permitted by specialized sta...

Страница 3: ...ons Manual Revision 3 0 PRSU 4 PRSU 5 Output Contacts A1 A2 13 14 23 24 33 34 41 42 S33 S34 S11 S12 S21 S22 Power supply inputs Safety relays normally open Auxiliary relay normally closed RESET mode c...

Страница 4: ...onitoring of the switches sensors will only occur once a RESET signal is received by bridging S33 and S34 with an appropriately rated wire See Pages 5 through 7 of this manual for more information Aft...

Страница 5: ...otch on the rear of the unit for DIN Rail attachment Electrical Connections Wire the device based on which of the following options best suits the target application RESET Mode Control Wiring 1 Automa...

Страница 6: ...he closure is broken and a RESET signal is manually generated by the operator via a mechanical N O pushbutton or switch 3 Conditional In this operating mode the RESET signal cannot propagate unless al...

Страница 7: ...to de energize Warning For this configuration to work as intended the series resistance between each end of the sensor s conductors cannot exceed 10 Additionally the short circuit resistance between...

Страница 8: ...no terminal of the device is connected to a live voltage before continuing 2 Unscrew terminals A1 and A2 from the device before removing any other connections 3 One at a time free connections from the...

Страница 9: ...es In cases where either one or both Channel LEDs is OFF during normal operation please verify that the device is properly wired If the problem persists the device is no longer capable of service Reti...

Страница 10: ...ifetime 105 switching cycles DC 24V 2A 105 switching cycles DC 24V 2A Creeping Distance and Clearance EN 50178 at pollution grade 2 over voltage category 3 250V Basis isolation over voltage category 3...