LED display is on, no mist or 
little mist is produced

Tank leakage

1

2

1

Mist height is low, damping 
surrounding desk or floor.
Condensation forms around 
humidifier or on windows 
and walls

Poor humidification

Tap water may contain too 
much minerals

Replace with filtered or 
distilled water or use with a 
TaoTronics Demineralization 
Cartridge

White Dust Appears / Black 
coating in the base flakes off

Unit needs to be cleaned

Strange Odor

Water is going down to the 
water reservoir

This is normal while it is 
working

Strange water noise

Unit works for too long

Power off and place in a 
well-ventilated place for 10 
minutes

Humidifier is getting too hot

Not enough water inside the 
tank

Refill and reinstall the water 
tank
Adjust to maximum mist
Check if current humidity is 
higher than preset humidity, 
reset humidity to a higher 
level
Remove the tank, empty 
the base & replace the 
filled tank on the empty 
base

Feel if air comes out from 
the the nozzle, if yes, then 
clean water scale on the 
atomizer as instructed

Mist level is set too low

Preset humidity is set too low

The base might be overfilled

Mineral buildup on atomizer

Check for possible cracks in 
the tank, replace if 
necessary 

Tighten the tank cap

Check the tank cap for 
rubber ring, rubber cap 
and spring, contact us if 
any is missing
Ensure the      spring is 
secured properly to the 
tank allowing water to pass 
through to the base

Tank may be damaged

Tank cap is not tightened 
securely

     Rubber ring was not 
installed on tank cap

     Spring stuck

1. Check if the room is too 
     humid, adjust to lower 
     mist, 40%-60% works best
2. Open door and windows, 
     or change to a larger 
     room
Humidifier should be 
placed on a hard flat 
surface, 2 feet above the 
floor, 12 inches away from 
the wall. Point Mist Outlet 
away from wall or window

Raise the room temperature 
to 25°C/77°F

Mist level is set too high for 
the room size

Air inlet is blocked

Low indoor temperature 
leads to liquefaction

1-1. Adjust to maximum mist
1-2. Close door or windows to 
       reduce air ventilation, or 
       change to a smaller room

Humidifier should be 
placed on a hard flat 
surface, 2 feet above the 
floor, 12 inches away from 
the wall
Raise the room temperature 
to 25°C/77°F

Mist level is set too low for the 
room size

Air inlet is blocked

Low indoor temperature 
leads to liquefaction

Clean the humidifier as 
instructed
Leave the empty water tank 
open in a cool place for 12 
hours without the water 
tank cap attached

Содержание TT-AH001

Страница 1: ...INC Address 46724 Lakeview Blvd Fremont CA 94538 Manufacturer Shenzhen NearbyExpress Technology Development Co Ltd Address 333 Bulong Road Shenzhen China 518129 MANUFACTURER Learn more about the EU De...

Страница 2: ...Setting Nightlight Sleep Mode Humidity Setting Low Water Protection Auto Shut off the Humidifier CLEANING AND MAINTENANCE Caution Daily Maintenance Weekly Maintenance Scale Removal Instructions Disinf...

Страница 3: ...r in connection with the use of the product SAFETY INSTRUCTIONS The humidifier was made with safe and environmental protection materials it has been certified and complied with the requirement of sale...

Страница 4: ...t is on to avoid damaging the product or causing injury 2 DO NOT clean the unit while it is connected to a power source or while it is on 1 DO NOT move or tilt the humidifier while it is in operation...

Страница 5: ...air or adjust any electrical or mechanical functions on this humidifier Doing so will void your warranty TIMER NIGHTLIGHT SLEEP MIST ON OFF HUMIDISTAT 1 x TaoTronics Humidifier Model TT AH001 1 x Clea...

Страница 6: ...water can go from the tank to the reservoir Put the nozzle back on 5 TIMER NIGHTLIGHT SLEEP MIST ON OFF HUMIDISTAT 1 2 3 4 1 If tap water is too hard it is recommended to use filtered or distilled wat...

Страница 7: ...e timer will flash three times to confirm your setting Once set the LED display will show the countdown timer and the environment humidity level alternately When time is up the unit will automatically...

Страница 8: ...NTENANCE Caution 1 DO NOT submerge the base in water 2 Make sure water does not enter the base through the air outlet air inlet or the control buttons and LED display 3 DO NOT wash any part of this hu...

Страница 9: ...Instructions 1 Follow steps 1 2 of the previous section on scale removal 2 Fill the water tank half full Add in tsp of bleach Place the tank cap back on Swish the solution around in tank Place the tan...

Страница 10: ...l buildup on atomizer Check for possible cracks in the tank replace if necessary Tighten the tank cap Check the tank cap for rubber ring rubber cap and spring contact us if any is missing Ensure the s...

Страница 11: ...hin 1 business day advise you how to correct the problem yourself or instruct you on how to return the defective unit back to us for repair or replacement We can only provide after sales service for p...

Страница 12: ...www taotronics com...

Отзывы: