background image

A. 

GENERAL INFORMATION 

This manual provides you with the information for proper use and maintenance of the 

TAR  High  Pressure  Washer.  Please  carefully  follow  the  instructions  provided.  The 

manufacturer  /  supplier  is  not  liable  for  any  damage  to  people  or  goods,  or  to  the 

system itself, if the equipment is used differently from as described in this manual. 

This  manual  is  provided  to  the  user  /  technician  for  correct  use  of  the  TAR  High 

Pressure Washer. Information provided in this manual does not replace regulations on 

safety at work currently in force. Therefore, the user should comply with the regulations 

in the country where the cleaner is installed, as well as following common sense rules. 

Do  not  use  the  product  if  you  notice  any  defect  or  wear  that  may  compromise  the 

original safety standards. The user or the maintenance technician must report any fault 

to the supplier. The machine is meant for specific applications. Do not modify and /or 

use it for applications other than the specified ones. 

Instructions,  drawings,  tables  and all  the  contents  of this document  are  confidential 

technical  documentation  and  are  the  exclusive  property  of 

TANONG  Precision 

Technology Co. Ltd.

 No information may be released to third parties without written 

permission by 

TANONG Precision Technology Co. Ltd

. Descriptions and images in 

this document are meant as indications and practical examples. They may be modified 

at  any  time  and  without  prior  notice.  If  further  technical  and  functional  details  are 

needed, please contact the manufacturer / supplier. 

 

IMPORTANT

 

a.  Please read the information contained in this manual since they will provide 

you  with  the  information  and  instructions  required  for  safe  installation,  use 

and maintenance. 

b.  Keep this booklet in a safe place and make it available for future reference. 

c. 

On delivery, check for any possible damages due to transport. 

Содержание TAR 12/120 M1

Страница 1: ... Operating and Maintenance Manual CONTENTS A GENERAL INFORMATION B SPECIFICATION C PREPARATION BEFORE OPERATION D SAFETY INSTURCTIONS E OPERATION INSTRUCTIONS F TROUBLESHOOTING G PERIODIC INSPECTION MAINTENANCE H WARRANTY ...

Страница 2: ...chnician must report any fault to the supplier The machine is meant for specific applications Do not modify and or use it for applications other than the specified ones Instructions drawings tables and all the contents of this document are confidential technical documentation and are the exclusive property of TANONG Precision Technology Co Ltd No information may be released to third parties withou...

Страница 3: ...se possible death or sustain serious injury It indicates that an unfair use may highly cause possible death or sustain serious injury It indicates that an unfair use may highly wound the user and or damage the product also is possible to bring out an unpredictable event ...

Страница 4: ... M3 12 L min 120 bar 3HP three phase 58Kg 1 TAR 12 180 M1 12 L min 180 bar 5HP single phase 67Kg 1 TAR 12 180 M3 12 L min 180 bar 5HP three phase 58Kg 1 TAR 17 120 M1 17 L min 120 bar 5HP single phase 67Kg 1 TAR 17 120 M3 17 L min 120 bar 5HP three phase 67Kg 1 TAR 15 200 M3 15 L min 200 bar 7 5 HP three phase TAR 15 250 M3 15 L min 250 bar 10 HP three phase TAR 17 230 M3 17 L min 230 bar 10HP thr...

Страница 5: ...ensor system would initiate the protective mechanism for motors When red indicating light is on it means the cleaner is energized normally When it blinks on the other hand it means the pump runs idle suck in air without water and the automatic mode is locked in order to prevent running abnormally When yellow indicating light is on it means the cleaner has run for 300 hours and it is needed to chan...

Страница 6: ...s blink it means water leakage has occurred for 3 4 times and the automatic mode would be locked and stop spraying water If you want to keep using automatic mode turn the knob switch to OFF or MANUAL MODE Indicators of malfunction or water leakage ...

Страница 7: ... of high pressure pump and the water inlet fitting of spray gun c Please use open end wrench to tighten filter onto water inlet end of pump Check filter sieve has been installed properly before connecting hose with the coupling of filter 3 Connected to water supply It is recommended to use 3 4 inch or the high pressure hose with minimum section diameter of 14 mm The inlet water amount should not b...

Страница 8: ...ould accord with the standard of CEI364 including the requisites of earth wire fuse and residual current circuit breaker with the sensitivity less than 30mA The voltage difference of the power supply should not exceed 5 of the rated voltage Please ensure that power cable should not be longer than 10m with the minimum section of 3 5mm2 If you need longer cable please contact the specialized Technic...

Страница 9: ...pting any cleaning or maintenance Fail to do so may cause electric shock 4 If any important part gets damaged stop using this machine immediately 5 The cleaner or electrified circuit including every installation cable and electric socket should not be spilled with water Keep the plug and wire dry and clean and do not touch it with wet hands Carefully remove the plug from the electric socket and do...

Страница 10: ...er gun please hold tight the gun because of strong recoil Do not spray at people animals electric instrument on using of this machine When you do not use it please turn off the safety switch on the gun If the temperature is possible to drop to less than 0 oC in winter the remaining water in the pump cylinder is likely to freeze Do not use this cleaner at this time If you want to use it please add ...

Страница 11: ...t If you want to continue to apply automatic mode please change to manual mode and undergo troubleshooting procedure before you turn to automatic mode c This cleaner is installed with circuit breaker of overload switch d When the yellow light of the indicator for 300 hours blinks which only provides the information of changing oil The automatic mode would command the cleaner not to work unless you...

Страница 12: ...w Rate 21 L min Thread Type NPT 1 4 External Diameter 36 mm Full Length 100 mm Weight 130 g b Matching table of pressure bar and flow rate L min of different types of nozzles Nozzle Specification Operational Pressure Unit Bar 80 100 120 140 170 200 220 035 7 2 8 0 8 7 9 4 10 4 11 5 11 9 045 9 2 10 3 11 3 12 1 13 4 14 5 15 2 055 11 3 12 5 13 8 14 8 16 4 17 7 18 5 Nozzle Cleaning In order to avoid p...

Страница 13: ... procedures please turn the switch to OFF state and break the power supply Remove the wire from the power and roll up carefully avoiding to bend it Remove the high pressure hose from the cleaner and roll up carefully avoiding to bend it Remove the spray gun and store it appropriately After the motor cools down to room temperature clean the water logging on the surface of this machine and put it in...

Страница 14: ...standby Valve could not work normally Pipe or gun could not fit closely Send to repair Change gasket The high pressure cleaner fails to reach maximum pressure The bolt of pressure spring of unloader valve has not been fastened Nozzle is on low pressure state The nozzle is worn The internal parts of unloader valve and seals are worn out Plunger seal gasket is worn out Fasten the pressure spring set...

Страница 15: ...al mode to let the air comes out Check whether the water supply feeds water or not Inflow of water into pump crankcase Water seal or oil seal is worn out Send to repair Both yellow and red light blink at the same time Abnormal water leakage for 3 4 times Turn the knob switch to STOP or Manual mode and then it could go back to Automatic mode and spray water normally ...

Страница 16: ...commendation 1 Routine Maintenance Maintenance Schedule Items Job Before operation Water inlet filter Check if there is blockage or dirt Pump Check the oil quantity Every 50hrs Motor and pump Change oil Limited for 1st time use Check if the pump and motor has been fixed firmly Check if electric control function is normal Pipe and power supply Check if spray pipe and wire has been fixed firmly Ever...

Страница 17: ...3 Exploded view Drawing of AR RKA High Pressure Pump Accessories 4 Parts list of AR RKA high pressure pump ...

Страница 18: ...d installer Use of non original or not specified parts for the cleaner The damages caused by natural disasters faulty usages or consumable purposes Manufacturer shall not be liable for any further loss damages or expenses including incidental or consequential damages directly or indirectly arising from the sale or use of this product This warranty does not cover repair or replacement of any item t...

Отзывы: