Tannoy VSXNET Series Скачать руководство пользователя страница 16

8. Software Installation 

16    

VSXNET Subwoofer Operation Manual  rev 2.0.0 

The control panel shows the model name (not editable), and firmware 
version for the device. The device properties panel also have an editable 
Configuration Name, and Loudspeaker name, the latter will appear in the 
tree menu after editing. Each panel will in addition have a complete set of 
controls relating to the adjustable parameters within the device (press the 
EQ/DELAY tab to access this section). Each control will contain the current 
parameter value (see 

Parameter Synchronisation

).

Single parameters may be adjusted ‘live’ whilst ‘On-line’.

Controls have standardised properties that allow them to work in a 
consistent way across various control panels for different devices. Many 
controls will allow the mouse wheel to be used for fine adjustments, or 
the keyboard as an alternative (see 

Keyboard Shortcuts

). When using 

the keyboard or the mouse wheel, it is necessary to have the control in 
question ‘in focus’. You can bring a control into focus either by tabbing to 
it (using the Tab key), or by clicking on it with the mouse. Focus is often 
shown as a dotted rectangle around part of the control.

Drop-Down Selector Boxes

These are for selecting one item from a number of possibilities in a list. 
Click the arrow on the right-hand end of the control to cause it to display 
a list of the options. Click on the text for that option to select it. If there are 
many options to choose from, a scroll-bar will be shown, allowing you to 
scroll up and down the list by clicking the scroll arrows. Note that once the 
control is highlighted, the PGUP, PGDWN and Arrow keys or the mouse 
wheel may also be used to change the selection.

Spin Boxes

The value would normally be adjusted by clicking on the top button to 
increase the displayed value, or on the bottom button to reduce the 
displayed value. Holding the mouse button whilst on a button will after 
a short delay cause the repeat mechanism to repeatedly increment or 
decrement the value. Alternatively, values may be typed into the value box 
directly. To do this, click in the value box and type in the new value. The 
value you type in may include a minus sign, a decimal point, and/or an 
engineering multiplier, such as ‘k’ to signify a multiplication of 1000. This 
may appear at the end of the typed string, or may be used instead of a 
decimal point (such as 6k2 to mean 6200). For the value to be accepted, 
you can either click outside the control (such as on another control), 
or press the Enter key. Once a control button is highlighted, the PGUP, 
PGDWN and Arrow keys a mouse wheel may also be used to adjust  
the value.

Buttons

Buttons generally have two states; depressed (active) and non-depressed 
(inactive). Generally, the button will apply the condition that is labelled 
when it is depressed. The space bar may be used to activate a highlighted 
button.

Faders

Faders provide a linearly traversing button, which may be dragged using 
a pressed mouse to adjust the value. These sometimes also have an 
associated value box for showing the numerical value of the parameter. 
Once the control is highlighted, the PGUP and PGDWN keys may be used 
for coarse adjustment, and the Arrow keys or the mouse wheel may be 
used to for fine adjustment. Also see 

VNET Control Panel

Содержание VSXNET Series

Страница 1: ...VSXNETSERIES High performancesubwoofers Operation Manual ...

Страница 2: ...en moving the cart apparatus combination to avoid injury from tip over 11 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been droppe...

Страница 3: ... Cooling 6 6 3 LED functions 7 6 4 Limiters 7 6 5 Audio Connections 7 6 6 User DSP On Off 8 7 Network Connections 9 7 1 Linking Cabinets 10 8 Software Installation 11 8 1 Updating Firmware 20 9 Equalisation 22 10 Rigging and Safety Procedures 23 11 SECUR ET VEB Eyebolt 24 12 Dimensions 24 13 Technical Specifications 27 14 Service Parts Accessories 28 15 Warranty 29 16 EU Declaration of Conformity ...

Страница 4: ...are housed in rugged durable birch ply enclosures with ergonomic Integrip carry handles and an integrated pole mount recess Coupling VSXNET Series subwoofers to VX and VXP Series full range loudspeakers via the optional VTH pole mount facilitates portable PA applications without need for tripod stands 3 Unpacking Each Tannoy VSXNET Series subwoofer is carefully tested and inspected prior to shipme...

Страница 5: ...twork Amplifier DSP Panel Power LED A LIMIT NETWORK FOUND LED displays DSP limiter action for both output channels Also duplicates the function of the front mounted network found LED A LIMIT NETWORK FOUND LED displays DSP limiter action for both output channels Also duplicates the function of the front mounted network found LED XLR FEMALE AUDIO INPUT This is a lockable XLR line input socket for co...

Страница 6: ... connectors which mate with the Neutrik NAC3FCA Cable connector quick lock with a securing lever for power in This AC mains connector is supplied with each VNET product The amplifier operates between the ranges of 100 to 240 Volts the auto ranging power supply detects the mains voltage automatically and configures accordingly Replace the mains fuse only with the same T10A HBC type supplied by Tann...

Страница 7: ...d the LED will flash intensely as an aid to locate and identify loudspeakers connected on the network The red limit LED on the back panel also doubles as a network find LED duplicating the function of the blue front mounted LED 6 4Limiters The limiters are carefully set up to preserve the loudspeakers dynamic headroom by allowing short term transients to pass audible degradation in sound will only...

Страница 8: ... used by an operator who has been using the Podware software for editing EQ gain delay at the end of the performance he mutes the loudspeakers from within the software and the loudspeakers are returned to hire stock after the performance Next day there is a rush for a small hire comprising only a couple of VNET loudspeakers The speakers are taken to the small gig where the operator is not making u...

Страница 9: ...een failure would be isolated to only that particular node RS 485 is standard for sending serial data It uses a pair of wires to send a differential signal over distances up to 4000 feet 1200 m without a repeater The differential signal makes it very robust RS 485 is one of the most popular communications methods used in industrial applications where it s noise immunity and long distance capabilit...

Страница 10: ...ential for the network to function correctly 7 1LinkingCabinets The table below shows the standard straight through convention for CAT5 patch cables clip down These can be used between network nodes Bear in mind though that only Pins 1 2 5 are used to link the network together To aid the construction of very large networks each speaker provides a source of power 12 Volts on the network Link connec...

Страница 11: ... of the plumbing involved in developing software enabling developers to focus on the core business logic code Makes it easier than ever before to build deploy and administer secure robust and high performing applications The NET Framework is composed of the common language runtime and a unified set of class libraries You can check to see if you already have the NET Framework 1 1 installed by click...

Страница 12: ...ammes insert the CD 2 Select your destination Folder Click Next Open the CD contents Double click on the Setup exe icon The welcome screen will appear Click Next Scenario Required Processor Recommended Processor Required RAM Recommended RAM Client Windows Forms and Windows Services Pentium 90 MHz Pentium 90 MHz or faster 32 MB 96 MB or higher Server Pentium 133 MHz Pentium 133 MHz or faster 128 MB...

Страница 13: ...allation VSXNETSubwooferOperationManual rev2 0 0 13 3 Confirm Installation Click Next 4 If you accept the license agreement check I Agree Then Click Next 5 The programme will begin installing 6 Installation Complete ...

Страница 14: ...wing one click functions Open Opens a file which contains parameters for the device A dialogue will appear inviting you to choose a file to open Save Saves the current settings If you have previously opened or saved a file the configuration will be saved in the same file name otherwise a dialogue will appear inviting you to enter a file name If the settings have not changed since you last saved or...

Страница 15: ...red parameters in the devices thus retaining synchronisation When a file is opened online the new settings are not only set in the control panel they are also transferred to the device Controlling Devices When online the tree menus will show the connected VNET speakers on the network Double clicking on the model on the tree view will open the control panel for each respective device Each open pane...

Страница 16: ...king the scroll arrows Note that once the control is highlighted the PGUP PGDWN and Arrow keys or the mouse wheel may also be used to change the selection Spin Boxes The value would normally be adjusted by clicking on the top button to increase the displayed value or on the bottom button to reduce the displayed value Holding the mouse button whilst on a button will after a short delay cause the re...

Страница 17: ... Values may be typed into either the bandwidth or Q part of the box A Frequency Response curve shows the shape of each filter individually by colour and the combined effect of all equalisation in white There are also High Low shelving filters Speaker Properties At the top of the panel there are several pieces of information about the connected device which are only activated when going On line to ...

Страница 18: ...ed to emphasise by applying a positive Level parameter setting or de emphasising by applying a negative Level parameter setting a range of frequencies centred on the setting of the Frequency parameter and encompassing a frequency range determined by the Bandwidth parameter setting The two shelving filters allow all frequencies below that of the frequency parameter for the Low shelf or all frequenc...

Страница 19: ... amplifier muted for a short time while checks are made that all is well During this time the indicators will both be solidly on The signal is then gently faded up accompanied by rapidly flashing indicators Smooth Adjustment Whenever a parameter is changed VNET will assess the likely impact on the signal path and will intelligently smoothly ramp to the new value or mute for a short time if the cha...

Страница 20: ...om the network A firmware update will be common to all VNET products one file for all models Updating a devices firmware is straight forward 1 Download and save the new firmware file to disk 2 From the toolbar select Device Start Firmware Loader 3 The following message will appear 4 Click OK 5 Browse to the new firmware file select The following message will appear stating the old version number t...

Страница 21: ...e 9 After the download is complete the following message appears The DSP is updating at this point Do not power down the unit or disconnect any network cable at this point During the update a red bar will show the progress of the firmware update bottom right of screen 10 The device will then power cycle automatically The loudspeaker is now ready for normal operation ...

Страница 22: ...hould be applied gently and smoothly VNET full range loudspeakers are point source phase coherent designs and violent equalisation will be detrimental to the overall sound quality When a loudspeaker is used in close proximity to another comb filtering effects can create coverage problems comb filtering creates an uneven frequency response across the coverage area due to constructive and destructiv...

Страница 23: ...se other than that indicated in this guide is considered to be improper use Such use can be very dangerous overloading modifying damaging or assembling in a manner other than that clearly stated in the Operation Manual will compromise safety The component parts of any Tannoy Professional hardware device must only be assembled using the accessory kits supplied and in strict compliance with the Oper...

Страница 24: ...B M10 eyebolts are to be installed Replace these counter sunk M10 screws with the VEB M10 eyebolts Important It is imperative for safety reasons that two eyebolts each linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the fly points as indicated in the following illustrations Never suspend one enclosure from another to form an array or cluster usin...

Страница 25: ...onManual rev2 0 0 25 VSXNET15DR VSXNET18DR 250 0 9 84 580 0 22 83 580 0 22 83 508 0 20 00 494 0 19 45 422 0 16 61 43 0 1 69 Fly Points Fly Points 650 0 25 59 650 0 25 59 588 0 23 15 290 0 11 42 564 0 22 20 43 0 1 69 Fly Points Fly Points ...

Страница 26: ...twork link 1 x Neutrik Powercon 1 x female XLR input 1 x male XLR link 1 x RJ45 network in 1 x RJA5 network link 1 x Neutrik Powercon 1 x female XLR input 1 x male XLR link 1 x RJ45 network in 1 x RJA5 network link 1 x Neutrik Powercon Controls Indicators LED on front of cabinet behind grille wink indicator for locating assigning Power LED blue Signal LED green Limit LED red User DSP defeat switch...

Страница 27: ...Hz 3 dB output 22 kHz handwidth 0 05 1 kHz 3 dB output 22 kHz handwidth 0 05 1 kHz 3 dB output 22 kHz handwidth Input Impedance 5 6 k Ω unbalanced 11 2 k Ω balanced 5 6 k Ω unbalanced 11 2 k Ω balanced 5 6 k Ω unbalanced 11 2 k Ω balanced Output Power Programme 1200 W 1200 W 1200 W Input Sensitivity 1 4 V 5 5 dBu 1 4 V 5 5 dBu 1 4 V 5 5 dBu System Type Dual channel Class D Bridged Dual channel Cla...

Страница 28: ...r customers One element of this commitment is our after sales support which now incorporates our extended Limited Warranty In the event of any concern that is not addressed by this extended Limited Warranty we would ask you to contact us at care music group com For full warranty details including the extended Limited Warranty please visit http www music group com warranty aspx and register your pu...

Страница 29: ...l loudspeakers Range name VSXNET Models VSXNET 12 2BP VSXNET 15DR VSXNET 18DR Is are in conformity with the requirements of the following documents Ref No Title Edition BS EN 55103 1 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus 2009 for professional use Emissions BS EN 55103 2 Electromagnetic compatibility Product f...

Страница 30: ...16 Notes 30 VSXNETSubwooferOperationManual rev2 0 0 16 Notes ...

Страница 31: ...17 Notes VSXNETSubwooferOperationManual rev2 0 0 31 17 Notes ...

Страница 32: ...ontinuous research and development The introduction of new materials or manufacturing methods will always equal or exceed the published specifications All specifications are subject to change without notice Copyright c 2015 Music Group Innovation SC Ltd All rights reserved ...

Отзывы: