SERIES
7.5
ARRAYING VQ 60
A single VQ 100 can produce more power and clarity over its 100degree beamwidth area than many arrayed
solutions using multiple cabinets, a great advantage when considering your building aesthetics. A VQ 100 is not
designed to be arrayed.
Two VQ 60ʼs can be arrayed to produce a well defined horizontal coverage angle of 120 degrees.
The VQ array plate is designed to optimally array two VQ 60 cabinets. To fit the plate, set the boxes on the ground
with the rear edge of the cabinets touching. Remove the two M10 countersunk bolts and replace with either the
M10 screw or the supplied eyebolts. Locate the four M10 eyebolts from the fixings kit supplied and insert these
through the array plate into the rigging points in the cabinet. These will be used to pick up the array.Repeat the
same procedure at the bottom of the cabinets, use the M10 screw. If flying in a landscape orientation the M10
screw can be used on both array plates.
Note: All fixings should be thread-locked and torqued to 25Nm
Two independent pick-up points are recommended for suspending the array. The main pickup points are the two
rear eyebolts. The two front eyebolts may be used as safety points.
Item No.
Description
Quantity
1
M10 Plain Washer
8
2
M10 Spring Washer
8
3
Screw M10 x 50mm
8
4
Eyebolt M10
4
5
Array Bracket
2
21
VQ Manual V2.qxd:Layout 1 12/11/08 11:44 Page 21