13.  System Configurations & OEM Controllers 
 
 

With the vast array of digital loudspeaker management systems available it is inevitable that the user 
may opt to use a controller other than the TX2 & TDX2 as part of a large scale integrated system. The 
V12 has been designed to need no external equalisation to overcome system limitations. If the V12 is 
to be used alone with additional bass enhancement required and have the frequency response limits 
tighter than +/- 3dB as stated in section 11, then apply the parameters in the table below for 
optimised performance:- 
 
 

Parameter 

Unit/Name 

 

 

Gain 

(dB) 

User definable 

Delay 

(ms) 

User definable 

Polarity 

 

Positive 

 

HPF 

â

 

Freq (Hz) 

42.5  

Slope (dB/oct) 

24 

Filter Shape 

Butterworth 

 

 

LPF 

Freq (Hz) 

Thru 

Slope (dB/oct) 

NA 

Filter Shape 

NA 

 

 

 

Freq (Hz) 

62.5 

Level (dB) 

+7 

Type 

Parametric 

PEQ 1 

â

â

 

 

Q / Bandwidth 

2.5 / 0.3969 

 

Freq (Hz) 

130 

Level (dB) 

-2 

Type 

Parametric 

PEQ 2 

 

Q / Bandwidth 

2 / 0.5 

 

Freq (Hz) 

655 

Level (dB) 

-2.3 

Type 

Parametric 

PEQ 3 

 

Q / Bandwidth 

6.7 / 0.1487 

 

Freq (Hz) 

981 

Level (dB) 

+3.3 

Type 

Parametric 

PEQ 4 

 

Q / Bandwidth 

7.1 / 0.1403 

 

Freq (Hz) 

12500 

Level (dB) 

+3 

Type 

Hi Shelf 

PEQ 5 

 

Q / Bandwidth 

NA 

 
 

 

â

â

Note : When using the V12 with subs, set HPF @ 80 – 110Hz 

 

(24dB/oct LR) and omit PEQ1. 

 

Содержание POWER V12

Страница 1: ...User Manual...

Страница 2: ......

Страница 3: ...hnical Specifications 12 Rigging Suspension 12 1 General Safety Advice 12 2 Secur ET VMY Yoke bracket 12 3 Secur ET VMB Wall mounting Bracket 12 4 Secur ET VEB Eyebolts 12 5 Secur ET VTH Pole mount 12...

Страница 4: ...be removed to install an optional pole mount As a versatile low profile stage monitor the conical coverage pattern gives the performer greater freedom of movement than allowed by conventional horn lo...

Страница 5: ...the polarity of the wiring before the speaker system is flown A simple method of doing this without a pulse based polarity checker for LF units is as follows Connect two wires to the ve and ve termina...

Страница 6: ...e recommended that the same amplifiers be used throughout 6 Crossovers The V12 is supplied as standard for passive operation via the internal crossover network If higher peak outputs and additional lo...

Страница 7: ...tation By placing the V12 cabinets with the 30 degree angled rear panels together minimal dispersion pattern overlap is achieved guaranteeing an extraordinarily smooth transition In many applications...

Страница 8: ...is considered to be improper use Such use can be very dangerous as overloading modifying assembling in anyway other than that clearly stated in the manual or damaging Tannoy Professional hardware will...

Страница 9: ...M10 inserts in the cabinet The VMY adjustable yoke bracket then connects to the centre of these mounting plates using the M10 screws supplied These bracket pick up points which are in line with the br...

Страница 10: ...led Number on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2 8 M8 x 2...

Страница 11: ...ere are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more discrete installati...

Страница 12: ...the desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative sides...

Страница 13: ...n conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy V12 loudspeaker to be suspended at a user defined distance from the...

Страница 14: ...n 11 then apply the parameters in the table below for optimised performance Parameter Unit Name Gain dB User definable Delay ms User definable Polarity Positive HPF Freq Hz 42 5 Slope dB oct 24 Filter...

Страница 15: ...Digital System Controller 90 250V USA 15 Warranty No maintenance of the V12 loudspeakers is necessary All Tannoy professional loudspeaker products are covered by a 5 year warranty from the date of man...

Страница 16: ...d do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic distu...

Страница 17: ...Telephone 44 0 1236 420199 Fax 44 0 1236 428230 Tannoy North America Inc Suite 1 335 Gage Avenue Kitchener Ontario CANADA N2M 5E1 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonett...

Отзывы: