background image

5

5. Amplification & Power Handlin

g

As with all professional loudspeaker systems, the power handling is a function of voice
coil thermal capacity. Care should be taken to avoid running the amplifier into clip
(clipping is the end result of overdriving any amplifier). Damage to the loudspe aker will
be sustained if the amplifier is driven into clip for any extended period of time.
Headroom of at least 3dB should be allowed. When evaluating an amplifier, it is
important to take into account its behaviour under low impedance load conditions. A
loudspeaker system is highly reactive and with transient signals it can require more
current than the nominal impedance would indicate.

Generally a higher power amplifier running free of distortion will do less damage to the
loudspeaker than a lower power amplifier continually clipping. It is also worth
remembering that a high powered amplifier running at less than 90% of output power
generally sounds a lot better than a lower power amplifier running at 100%. An
amplifier with insufficient drive capability will not allow the full performance of the
loudspeaker to be realised.

It is important when using different manufacturers amplifiers in a single installation that
the have very closely matched gains, the variation should be less than +/ - 0.5dB. This
precaution is important to the overall system balance when only a single
compressor/limiter or active crossover is being used with multiple cabinets; it is
therefore recommended that the same amplifiers are used throughout.

6. Power Selection (i8T AW)

Determi ne the maximum power in watts needed at each speaker location. The i8 AW
transformer can be tapped at 60W, 30W, 15W, & 7.5W (70V line only) via the rotary
switch located on the metal plate at rear of the loudspeaker. When the relevant
tappings have been se lected add the individual wattages required at all speakers and
select an amplifier with a rating equal to or exceeding the total wattage required. All of
the transformer primaries should be connected in parallel to the output of this amplifier.
If for example, you select the 7.5- Watt transformer tap, it means that at full rated
amplifier output the speaker will receive the full 7.5 Watts. If the amplifier gain is
reduced each speaker will receive a proportional amount of power, maintaining the
overall syst em balance.

When calculating amplifier wattage requirements for a system, it is recommended that
a generous wattage safety margin (3dB of headroom) be left so that the system does
not have to operate continuously at its full rated output.

7. Equalisation

The i8 AW loudspeaker is designed to need no equalisation or correction to overcome
system limitations. As a result, it will only need equalisation to compensate for difficult
acoustic environments.

Over- equalisation can reduce system headroom, and int roduce phase distortion
resulting in greater problems than cures. If equalisation is required then it should be
applied gently and smoothly. The i8 AW loudspeaker is a point source, phase coherent
design and violent equalisation will be detrimental to the overall sound quality.

Содержание i8 AW

Страница 1: ...i8 AW i8T AW USER MANUAL ...

Страница 2: ...abling 3 4 Polarity Checking 4 5 Amplification Power Handling 5 6 Power Selection i8T AW 5 7 Equalisation 5 8 Dimensions 6 9 Hardware 7 10 Performance Data 8 11 Polar Data 9 12 Technical Specifications 10 13 i8 AW Service Parts Accessories 11 14 Warranty 11 ...

Страница 3: ...ulti ng in a smooth uniform frequency response over a wide area of coverage The sophisticated CAD designed waveguide combines 60 conical dispersion and excellent acoustic impedance characteristics For applications requiring extended low frequency enhancement a range of Tannoy sub bass systems are available and can be used in conjunction with the i8 AW 2 Unpacking Every Tannoy i8 AW product is care...

Страница 4: ...3 2 7 1 8 8 6 5 4 3 6 50 2 5 4 0 6 0 0 69 0 43 0 29 8 6 5 4 3 6 17 0 11 0 7 2 100 2 5 4 0 6 0 1 38 0 86 0 58 17 0 11 0 7 2 35 0 22 0 14 0 4 Polarity Checking It is most important to check the polarity of the wiring A simple method of doing this without a pulse based polarity checker fo r LF units is as follows Connect two wires to the ve and ve terminals of a PP3 battery Apply the wire which is co...

Страница 5: ...s it is therefore recommended that the same amplifiers are used throughout 6 Power Selection i8T AW Determine the maximum power in watts needed at each speaker location The i8 AW transformer can be tapped at 60W 30W 15W 7 5W 70V line only via the rotary switch located on the metal plate at rear of the loudspeaker When the relevant tappings have been se lected add the individual wattages required a...

Страница 6: ...6 8 Dimensions ...

Страница 7: ... M8 Bolts to fix t he loudspeaker in position The loudspeaker can be mounted either horizontally or vertically using the MB8 bracket Figure 9a 9b The i8 AW also has threaded M6 holes for Omni Mount Series 75 Figure 9d and other bracketry Figure 9a Figure 9b Figure 9c Figure 9d NOTE The installation of this product must be carried out in conformity with local building codes and standards If necessa...

Страница 8: ...8 10 Performance Data Anechoic Frequency Response 1watt 1m Impedance ...

Страница 9: ...9 11 Polar Data ...

Страница 10: ... Enclosure 16 litre polypropylene Finish Charcoal or White Protective Grille Perforated aluminium Connectors 1 x Speakon NL4MP 2 x 4mm binding posts Fittings 1 x 35mm pole mount 2 x M8 inserts Dimensions 388 x 280 x 260mm 15 3 8 x 11 x 10 1 4 Weight each 8 5kg 18lbs 10oz Shippin g Dimensions 450 x 570 x 340mm 15 3 8 x 22 3 8 x 13 3 8 Shipping Weight 17 9kg 39lbs 5oz NOTES 1 Average over stated ban...

Страница 11: ...r or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Tannoy Ltd Rosehall Industrial Estate Coatbridge Strathclyde ML5 4TF Scotland Telephone 01236 420199 National 44 1236 ...

Страница 12: ...bsite www tannoy com Tannoy North America Inc 335 Gage Avenue Suite 1 Kitchener Ontario Canada N2M 5E1 Tel 519 745 1158 Fax 519 745 2364 e mail inquiries tannoyna com Website www tannoy com Tannoy Nederland b v Anthonetta Kuijlstraat 19 3066 GS Rotterdam Tel 010 286 0554 Fax 010 286 0431 e mail info tannoy nl Website www tannoy nl ML 3rd October 2003 ...

Отзывы: