background image

 
 

11. Technical Specifications 

 
 
 
Frequency response (1)  +3/- 6dB   

90Hz - 20kHz 

 

Recommended Amplifier Power 

 

up to 180 watt / 8 ohm

 

 
Power Handling    

 

 

Average (2) 

Programme 

Peak (10ms) 

 

 

 

 

 

 

 

 

90-watt   

180 watt   

360 watt

 

 
Sensitivity (1) 
2.83 volt @ 1m  

 

 

 

89dB

 

 92dB (half space) 

 
Maximum SPL (3)  

 

 

Average  Peak 

Average (half space) Peak (half space)

 

@ 1m  

 

 

 

 

108dB 

114dB 

111dB 

 

117dB 

 

Maximum SPL (3) With THP60 Transformer 

Average  Peak 

Average (half space) Peak (half space)

 

@ 1m  

 

 

 

 

106 dB 

112dB 

109dB 

 

115dB 

 

Impedance  

 

 

 

Nominal  8 

 

Minimum  6.2 

 

 
Nominal Dispersion   

 

 

70

°

 Vertical 

110

°

 Horizontal 

 

Voltage tap ratings for 100V -line 

 

Position  Watts 

 

transformer version 

 

 

Left 

15 

677 

Middle 

30 

333 

Right 

60 

166 

 

Transformer (i7T Contour) 

 

 

Insertion loss 

0.9 dB 

Primary Taps 

60, 30, 15 Watt 

Voltage Taps 

100, 70, 25 Volts

 

 
Driver Complement 

 

 

×

 1” Neodinium HF unit 

×

 4” LF drivers 

 

Crossover Point   

 

 

1.8, 2.5 kHz 

 
Enclosure 

 

 

 

7 litres 

 
Finish 

 

 

 

 

Dark grey or White 

 
Protective Grille    

 

 

Perforated

 

Stainless Steel

 

 
Connectors 

 

 

 

×

 4mm binding posts

 

 
Fittings    

 

 

 

×

 M6 inserts for MB7 Bracket 

 

Dimensions  

 

 

 

560mm (H) 

×

 130mm (W) 

×

 146mm (D) 

22.06” (H) 

×

 5.12” (W) 

×

 5.75” (D) 

 

Weight   

 

 

 

8.1kg (17.86 lbs.) 

 

Shipping Dimensions

 

 

 

650mm (H) 

×

 210mm (W) 

×

 220mm (D) 

 

 

 

 

 

25.61” (H) 

×

 8.27” (W) 

×

 8.67” (D) 

 
Shipping Weight   

 

 

9kg (19.84 lbs.)

 

 
 
 
 
 

NOTES:

    

(1) Average over stated bandwidth. Measured at 1m on axis, in an anechoic chamber. 
(2) Long term power handling capacity as defined in EIA standard RS  - 426A.  
(3) Unweighted pink noise input, measured at 1m  

 
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will 
always equal or exceed the published specifications which Tannoy reserve the right to alter without prior notice. Please verify the latest 
specifications when dealing with critical applications. 

Содержание i7 T

Страница 1: ...i7 Contour i7T Contour USER MANUAL ...

Страница 2: ...ity Checking 5 Amplification Power Handling 6 Power Selection 7 Equalisation 8 Dimensions 9 Hardware 10 Performance Data 11 Technical Specifications 12 Troubleshooting Guide 13 i7 Contour Recommended Service Parts Accessories 14 Warranty 15 Declaration of Conformity ...

Страница 3: ...ith greater bandwidth than other 70 100V line systems For applications requiring extended low frequency enhancement a range of Tannoy sub bass systems are available and can be used in conjunction with the i7 Contour 2 Unpacking Every Tannoy i7 Contour product is carefully inspected before packing After unpacking your loudspeakers please inspect for any exterior physical damage and save the carton ...

Страница 4: ...manufacturer check the polarity at the amplifiers as well as the loudspeakers 5 Amplification Power Handling As with all professional loudspeaker systems the power handling is a function of voice coil thermal capacity Care should be taken to avoid running the amplifier into clip clipping is the end result of overdriving any amplifier Damage to the loudspeaker will be sustained if the amplifier is ...

Страница 5: ...plifier output the speaker will receive the full 15 watts If the amplifier gain is reduced each speaker will receive a proportional amount of power maintaining the overall system balance When calculating amplifier wattage requirements for a system it is recommended that a generous wattage safety margin 3dB of headroom be left so that the system does not have to operate continuously at its full rat...

Страница 6: ...n the M6 bolts to fix the loudspeaker into position The loudspeaker can be mounted either horizontally or vertically using the MB7 bracket fig 2 Figure 1 Figure 2 NOTE The installation of this product must be carried out in conformity with local building codes and standards If necessary consult your local safety standards officer before installing any product Alternatively check any laws or bylaws...

Страница 7: ...10 Performance Data Frequency Response Impedance ...

Страница 8: ...OCTAVE BAND POLAR CHARACTERISTICS ...

Страница 9: ......

Страница 10: ...ver Complement 1 1 Neodinium HF unit 4 4 LF drivers Crossover Point 1 8 2 5 kHz Enclosure 7 litres Finish Dark grey or White Protective Grille Perforated Stainless Steel Connectors 2 4mm binding posts Fittings 2 M6 inserts for MB7 Bracket Dimensions 560mm H 130mm W 146mm D 22 06 H 5 12 W 5 75 D Weight 8 1kg 17 86 lbs Shipping Dimensions 650mm H 210mm W 220mm D 25 61 H 8 27 W 8 67 D Shipping Weight...

Страница 11: ...od electrical connection with amplifier outputs and loudspeaker inputs A bad connection can increase resistance which will substantially reduce the output or make cracking noises which are unrelated to signal content If using multi strand loudspeaker cable be sure no strands of cable are causing short circuits between the positive and negative terminals of the amplifier outputs and or loudspeaker ...

Страница 12: ... dealer or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Professional Division Tannoy Ltd Coatbridge Scotland ML5 4TF Telephone 01236 420199 National 44 1236 420199 Inte...

Страница 13: ...onstructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended Details of the Apparatus Model Number i7 Contour Associated Technical File EMCi7 Applicab...

Страница 14: ...230 Internet http www tannoy com TGI Tannoy 300 Gage Avenue Kitchener Ontario CANADA N2M 2C8 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijistratt 19 3066GS Rotterdam THE NETHERLANDS Telephone 015 2124034 Fax 015 2125213 Tannoy is a member of the Group of Companies Issue 1 Part No 6481 0307 ML 24 th August 1999 ...

Отзывы: