TECHNICAL SPECIFICATIONS

System

Frequency Response (-3dB) 

(1)

Frequency Range (-10dB) 

(1)

System Sensitivity (1W @1m) 

(2)

Nominal Coverage Angle

Coverage Angle (1kHz to 6kHz)

Directivity Factor (Q)

Directivity Index (DI)

Rated Maximum SPL

Power Handling 

(3)

Average
Programme
Peak

Recommended Amplifier Power

Nominal Impedance

Transformer Taps

(via front rotary switch)
70V

100V

Distortion

1% Full Power
250Hz
1kHz
10kHz

10% Full Power
250Hz
1kHz
10kHz

Crossover Point

Notes
(1) Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber
(2) Unweighted Pink noise input, measured at 1m on axis
(3) Long term power handling capacity as defined in EIA - 426B test

CVS8

79Hz - 21kHz

60Hz - 24kHz

93dB (1W = 2.45V for 6 Ohms)

90 degrees conical

84 degrees conical

14.7 averaged 1kHz to 6kHz

11.7 averaged 1kHz to 6kHz

111dB (average)
117dB (peak)

60W
120W
240W

120W @ 6 Ohms

6 Ohms

60W / 30W / 15W / 7.5W / OFF
& low impedance operation

60W / 30W / 15W / OFF
& low impedance operation

0.33%

0.25%

0.15%

0.63%

0.12%

0.03%

1.10%

0.25%

0.55% 0.70%
0.52%

0.03%

6kHz

Transducers

Low Frequency

High Frequency

Coaxial
200 mm (8.00") mineral loaded cone material

19mm (0.75")

Physical

Enclosure 

   

Back can
Baffle
Grille

Safety Features

Clamping Design

Back Can

Cable Entry Options

Connectors

Safety Agency Ratings (pending) 

Hole Cutout Diameter

Dimensions

Bezel diameter

Front of ceiling to
rear of back can

Front of ceiling to
top of safety loop

Net Weight (ea)

Included Accessories

Optional Accessories

Zinc plated steel

Blind Mount (BM)

Reflex loaded UL 94V-0 rated ABS
Steel, with weather resistant coating

Safety ring located at rear of enclosure
for load bearing safety bond

Security toggle clamp

Cable clamp & squeeze connector for
conduit up to 22mm

Removable locking connector with sctrew
terminals with "loop through" facility

UL-1480, UL-2043, CE

320mm (12.6")

355.6mm (14.00”)

251.0mm (9.88”)

264.0mm (10.39”)

Template hole cutout size

250mm (9.84")

5.3kg (11.68lbs)

C Ring, tile bridge, paint mask,
cutout template, grille

Plaster (mud) ring

CVS6

TECHNICAL SPECIFICATIONS

System

Frequency Response (-3dB) 

(1)

Frequency Range (-10dB) 

(1)

System Sensitivity (1W @1m) 

(2)

Nominal Coverage Angle

Coverage Angle (1kHz to 6kHz)

Directivity Factor (Q)

Directivity Index (DI)

Rated Maximum SPL

Power Handling 

(3)

Average
Programme
Peak

Recommended Amplifier Power

Nominal Impedance

Transformer Taps

(via front rotary switch)
70V

100V

Distortion

1% Full Power
250Hz
1kHz
10kHz

10% Full Power
250Hz
1kHz
10kHz

Crossover Point

Notes
(1) Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber
(2) Unweighted Pink noise input, measured at 1m on axis
(3) Long term power handling capacity as defined in EIA - 426B test

CVS6

79Hz - 21kHz

60Hz - 24kHz

91dB (1W = 2.45V for 6 Ohms)

90 degrees conical

93 degrees

7.7 averaged 1kHz to 6kHz

8 averaged 1kHz to 6kHz

109dB (average)
115dB (peak)

60W
120W
240W

120W @ 6 Ohms

6 Ohms

60W / 30W / 15W / 7.5W / OFF
& low impedance operation

60W / 30W / 15W / OFF
& low impedance operation

2nd Harmonic

3rd Harmonic

0.439%

0.140%

0.396%

0.458%

0.235%

0.023%

2nd Harmonic

3rd Harmonic

1.16%

0.214%

1.014% 0.685%
0.944%

0.047%

2.5kHz

Transducers

Low Frequency

High Frequency

150mm (6.00") Mineral Loaded
polypropylene ICT™

19mm (0.75")

Physical

Enclosure

Back can
Baffle
Grille

Safety Features

Clamping Design

Back Can

Cable Entry Options

Connectors

Safety Agency Ratings 

Hole Cutout Diameter

Dimensions

Bezel diameter

Front of ceiling to
rear of back can

Front of ceiling to
top of safety loop

Net Weight (ea)

Included Accessories

Optional Accessories

Zinc plated steel
Reflex loaded UL 94V-0 rated ABS
Steel, with weather resistant coating

Safety ring located at rear of enclosure
for load bearing safety bond

Security toggle clamp

Cable clamp & squeeze connector for
conduit up to 22mm

Removable locking connector with sctrew
terminals with "loop through" facility

UL-1480, UL-2043, CE

250mm

279.5mm (11.01”)

246.5mm (9.70”)

258.5mm (10.18”)

4.75kg

C Ring, tile bridge, paint mask,
cutout template, grille

Plaster (mud) ring

Содержание CVS4

Страница 1: ...CVS 4 CVS 6 CVS 8 I N S T A L L A T I O N M A N U A L CVS 4 TEMPLATE CUTOUT SIZE 180mm CVS 6 TEMPLATE CUTOUT SIZE 250mm A T CVS 8 TEMPLATE CUTOUT SIZE 320mm...

Страница 2: ...NGS MECHANICAL INSTALLATION GUIDE FOR SHEET ROCK CEILINGS MECHANICAL INSTALLATION INSTRUCTIONS FOR OPTIONAL PLASTER RING WIRING AND SETTING UP DIMENSIONS CVS 4 DIMENSIONS CVS 6 DIMENSIONS TECHNICAL SP...

Страница 3: ...event of any damage would you please notify your dealer immediately and retain your shipping carton as your dealer may ask you to return the faulty unit to them for inspection Each CVS loudspeaker is...

Страница 4: ...ATION CVS 4 CVS 6 CVS 8 Conduit Cable Clamp Mounting Wings Safety Tab Tuning Ports Rotary Switch Screws for mounting wings Tuning Ports Rotary Switch Screws for mounting wings Tuning Ports Rotary Swit...

Страница 5: ...ORIES Standard Accessories C Ring Tile bridge kit Note A tile bridge kit must always be used when installing into suspended ceiling tiles Grille Cut out template Paint Mask Optional Accessories Plaste...

Страница 6: ...tile bridge on top of the ceiling panel aligning the C ring over the hole and screw the C ring to the tile bridge using the fixings provided 3 Cut out the hole in the ceiling tile using a circular sa...

Страница 7: ...d the template provided 1 7 Connect a Secondary Support Line to safety tab Some construction codes require use of this secondary support point which should connect to a separate secure support point u...

Страница 8: ...ings Cut out the hole in the ceiling using a circular saw or pad saw 3 5 Go to section 7 for instructions on wiring then return to point 5 below 4 Connect a Secondary Support Line to safety tab Some c...

Страница 9: ...hether you wish to use the speaker in a low impedance or distributed line application 3 THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE NEVER CONNECT THE SPEAKER TO A 70 100 VOLT AMPLIFIER WHILE IT IS S...

Страница 10: ...10 8 1 CVS 4 DIMENSIONS CVS 4 TEMPLATE CUTOUT SIZE 180mm 174 8 6 88 14 7 0 58 202 5 7 97 214 9 8 46 213 0 8 39...

Страница 11: ...11 8 2 CVS 6 DIMENSIONS CVS 6 TEMPLATE CUTOUT SIZE 250mm 244 6 9 63 246 5 9 70 15 9 0 63 258 5 10 18 279 6 11 01...

Страница 12: ...12 8 3 CVS 8 DIMENSIONS CVS 8 TEMPLATE CUTOUT SIZE 320mm 355 6 14 00 19 6 0 77 251 0 9 88 264 0 10 39 315 2 12 41...

Страница 13: ...3 75W OFF low impedance operation 30W 15W 7 5W OFF low impedance operation 2nd Harmonic 3rd Harmonic 0 231 0 112 0 229 0 253 0 163 0 025 2nd Harmonic 3rd Harmonic 0 99 0 169 0 816 0 323 0 444 0 027 2...

Страница 14: ...OFF low impedance operation 60W 30W 15W OFF low impedance operation 2nd Harmonic 3rd Harmonic 0 439 0 140 0 396 0 458 0 235 0 023 2nd Harmonic 3rd Harmonic 1 16 0 214 1 014 0 685 0 944 0 047 2 5kHz Tr...

Страница 15: ...OFF low impedance operation 60W 30W 15W OFF low impedance operation 0 33 0 25 0 15 0 63 0 12 0 03 1 10 0 25 0 55 0 70 0 52 0 03 6kHz Transducers Low Frequency High Frequency Coaxial 200 mm 8 00 minera...

Страница 16: ...d by a 5 year warranty from the date of manufacture subject to the absence of misuse overload or accidental damage Claims will not be considered if the serial number has been altered or removed Work u...

Страница 17: ...ications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended...

Страница 18: ...s may be subject to further change Please contact the Tannoy website for the latest information REVISION DATE 03 March 2011 HUUV PYLJ 2 0 96 ZHSLZ LUX PYPLZ HUUV JVT PUMV JNYV W PU LYUH PVUHS JVT TLYP...

Отзывы: