7  Wiring and Setting Up

1. Open the wiring cover (if applicable) and locate  

the Euro-type connector plug and socket at the  

back of the speaker. (Fig.1)

2. For connection to an amplifier, use Pins 1 and 2

(Fig.2)

3. Close the wiring cover and tighten both screws  

on the cable clamp (if applicable). 

4. Use the rotary switch on the front of the unit  

to select low impedance (LoZ) mode or high   

impedance (70 V or 100 V) for distributed 

applications. 

The speaker is supplied in low impedance

mode. Never connect the speaker to a 

70 / 100 volt amplifier while it is set for 

low impedance.

CMS 503 LP models (all variants) use a 30 W 

transformer. In distributed line applications, the 

transformer can be tapped at 30 W, 15 W and 

 

7.5 W, with an additional 3.75 W tap for 70 V 

 

line systems.

8  CMS Series Dimensions

Please refer to the full CMS Series Operation 

Manual for dimensional drawings.

CMS 503DC LP & CMS 503ICT LP

Hole cut-out: 253 mm   Diameter

1

: 274 mm (10.79”)  

Height

2

: 98.6 mm (3.88”)

1

 Maximum, including bezel ring

2

 Maximum to top of connector, from lower 

  ceiling surface 

Fig.1

• Pin 1 is positive

• Pin 2 is negative

For connection to 

additional speakers 

in a distributed line,

Pins 3 and 4 are in 

parallel where:

• Pin 3 is negative

• Pin 4 is positive