Tannoy CMS501 Скачать руководство пользователя страница 7

Tannoy United Kingdom
Tannoy North America
Tannoy Deutschland
Tannoy France

T: 00 44 (0) 1236 420199
T: 00 1 (519) 745 1158
T: 00 49 (180) 1111 881
T: 00 33 (0)1 7036 7473

E: [email protected]
E: [email protected]
E: [email protected]
E: [email protected]

CMS501

Tannoy adopts a policy of continuous improvement and product specification is subject to change

CMS501 data file // issue 1.06 // 10.01.08

The Ceiling Monitor System shall consist of a 130mm (5.00") full range, point source ICTTM transducer mounted in a vented, injection moulded, paintable
front baffle in UL94V-0 ABS material.

The back can in both PI (pre-install) & BM (Blind-mount variants) shall be constructed of zinc plated steel. A recessed termination box shall be integrated with
the back can, a removable locking connector with screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be
provided by a clamping mechanism for use with plenum rated cable or conduit.

For prewiring the PI (pre-install) back can is provided with conduit knockouts (19mm / 22mm / 28mm, 0.75" / 0.87" / 1.14"). A safety ring is located on the
rear of the back can for a load bearing safety bond.

Performance of the ceiling monitor shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 105degrees (1kHz to
6kHz). Frequency response measured on axis shall be 74 Hz - 24kHz (-10dB from rated sensitivity, measured in an IEC baffle in an anechoic chamber) with
no equalization. Sensitivity shall be 89dB (1W @ 1m). Long term power handling capacity as defined in EIA-426B test shall be 50W, recommended amplifier
power 100W. The nominal system impedance shall be 6 Ohms (in low impedance setting).

The Ceiling Monitor System shall be equipped with a 30W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 30,
15, 7.5, 3.75 Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance
settings. A weather resistant perforated steel grille covers the transducer and switch.

Two support rails and one C-Ring shall be included with the ceiling monitor system.

Bezel diameter 210mm (8.27")
BM Front of ceiling to rear of back can 189.5mm (7.46"), Front of ceiling to top of safety loop 206.8mm (8.14")
PI Front of ceiling surface to rear of speaker unit 135.6mm (5.34"), Front of accessory back can bezel to top of safety loop 153.50mm (6.04")

The Ceiling Monitor System shall be the.....CMS501.

*70 Volt only

Architectural specifications

Содержание CMS501

Страница 1: ... combination of premium sonic quality for music and speech reinforcement and exceptional reliability The CMS501 is equipped with a low insertion loss 30W line transformer easily configurable to the following settings via front baffle mounted rotary tapping switch 70V systems 30W 15W 7 5W 3 75W OFF low Impedance operation 100V systems 30W 15W 7 5W OFF low Impedance operation Two CMS501 model versio...

Страница 2: ...es a policy of continuous research and development The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserves the right to alter without prior notice Please verify the latest specifications when dealing with critical applications System CMS501 Transducers 8001 4450 CMS501 BM White paintable 2 8001 4460 CMS501 PI White p...

Страница 3: ...ORMANCE MEASUREMENTS DI 1 10 100 100 1000 10000 50 60 70 80 90 100 110 10 100 1000 10000 100000 0 5 10 15 20 25 1 10 100 1000 10000 100000 50 60 70 80 90 100 110 10 100 1000 10000 100000 0 deg 10 deg 20deg 30deg 40deg Beamwidth 1 3 Octave 0 30 60 90 120 150 180 210 240 270 300 330 360 100 1000 10000 ANECHOIC FREQUENCY RESPONSE IMPEDANCE DIRECTIVITY INDEX 1m on axis frequency response frequency Hz ...

Страница 4: ...49 180 1111 881 T 00 33 0 1 7036 7473 E enquiries tannoy com E inquiries tannoyna com E anfragen tannoy com E ventes tannoy com CMS501 Tannoy adopts a policy of continuous improvement and product specification is subject to change CMS501 data file issue 1 06 10 01 08 PERFORMANCE MEASUREMENTS POLAR PLOTS 1 3 OCTAVE 100 Hz 125 Hz 160 Hz 200 Hz 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz 1 kHz 1 25 kHz...

Страница 5: ...s subject to change CMS501 data file issue 1 06 10 01 08 DIMENSIONAL SKETCHES TEMPLATE HOLE CUTOUT SIZE 190mm 7 50 CMS501 BM TEMPLATE HOLE CUTOUT SIZE 190mm 7 50 CMS501 PI 207 00 8 10 189 50 7 50 5 00 0 20 210 00 8 20 181 30 7 14 210 00 8 20 136 00 5 40 5 00 0 20 181 30 7 14 8001 4450 CMS501 BM White paintable 2 8001 4460 CMS501 PI White paintable 2 8001 4180 CMS501 Plaster Mud Ring Zinc plated st...

Страница 6: ...0 0 63 4 50 0 18 522 00 20 55 81 00 3 19 360 00 14 17 15 00 0 59 635 00 25 00 15 00 0 59 25 POSITIONS SUPPLIED ACCESSORIES C RING TILE BRIDGE OPTIONAL ACCESSORIES PLASTER MUD RING 60 00 2 36 180 00 7 09 205 00 8 07 230 00 9 06 255 00 10 04 280 00 11 02 305 00 12 01 650 00 25 59 10 00 0 39 188 00 7 40 254 00 10 00 The PI back can accepts direct connection to installed conduit in two ways using sque...

Страница 7: ... Performance of the ceiling monitor shall meet or exceed the following criteria The system shall have a conical coverage pattern of 105degrees 1kHz to 6kHz Frequency response measured on axis shall be 74 Hz 24kHz 10dB from rated sensitivity measured in an IEC baffle in an anechoic chamber with no equalization Sensitivity shall be 89dB 1W 1m Long term power handling capacity as defined in EIA 426B ...

Страница 8: ... T 00 1 519 745 1158 T 00 49 180 1111 881 T 00 33 0 1 7036 7473 E enquiries tannoy com E inquiries tannoyna com E anfragen tannoy com E ventes tannoy com CMS501 Tannoy adopts a policy of continuous improvement and product specification is subject to change CMS501 data file issue 1 06 10 01 08 NOTES ...

Страница 9: ... T 00 1 519 745 1158 T 00 49 180 1111 881 T 00 33 0 1 7036 7473 E enquiries tannoy com E inquiries tannoyna com E anfragen tannoy com E ventes tannoy com CMS501 Tannoy adopts a policy of continuous improvement and product specification is subject to change CMS501 data file issue 1 06 10 01 08 NOTES ...

Отзывы: