Tannoy B950 Скачать руководство пользователя страница 4

For a worldwide list of distributors, please contact Neutrik directly: -

N

EUTRIK

 AG:

+41 7529666

Cable choice consists mainly of selecting the correct cross sectional area in relation
to the cable length and the load impedance. A small cross sectional area would
increase the cables series resistance, inducing power loss and response variations
(damping factor).

Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This
will be perfectly satisfactory under normal conditions. In the case of very long cable
runs the wire size should exceed this, refer to the following table for guidance:-

CABLE RUN
(m)

C.S.A. OF EACH
CONDUCTOR (mm)

CABLE
RESISTANCE 

% POWER LOSS
INTO 8

 LOAD

% POWER LOSS
INTO 4

 LOAD

10

2.5
4.0
6.0

0.14
0.09
0.06

1.7
1.1
0.73

3.5
2.2
1.5

25

2.5
4.0
6.0

0.35
0.22
0.14

4.3
2.7
1.8

8.6
5.4
3.6

50

2.5
4.0
6.0

0.69
0.43
0.29

8.6
5.4
3.6

17.0
11.0
7.2

100

2.5
4.0
6.0

1.38
0.86
0.58

17.0
11.0
7.2

35.0
22.0
14.0

4. Polarity Checking

It is most important to check the polarity of the wiring before the speaker system is
flown. A simple method of doing this without a pulse based polarity checker for LF
units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery.
Apply the wire, which is connected to the +ve terminal of the battery to the speaker
cable leg, which you believe to be connected to pin 1+ of the speaker connector and
likewise the -ve leg of the battery to pin 1-.

If you have wired it correctly the LF drive unit will move forward, indicating the wiring
is correct. All that remains now is to connect the +ve speaker lead to the +ve
terminal on the amplifier and the -ve lead to the -ve terminal on the amplifier. If
however the LF driver moves backwards, the input connections need to be inverted.

If problems are encountered, inspect the cable wiring in the first instance. It should
also be noted that different amplifier manufacturers utilise different pin configurations
and polarity conventions, if you are using amplifiers from more than one
manufacturer, check the polarity at the amplifiers as well as the loudspeakers.

Содержание B950

Страница 1: ...B950 USER MANUAL...

Страница 2: ...rs Cabling 4 Polarity Checking 5 Amplification Power Handling 6 Crossovers 7 Equalisation 8 Positioning 9 Dimensions 10 Performance Data 11 Technical Specifications 12 Recommended Service Parts Access...

Страница 3: ...Unpacking Every Tannoy product is carefully inspected before packing After unpacking your B950 please inspect for any exterior physical damage and save the carton and any relevant packaging materials...

Страница 4: ...larity Checking It is most important to check the polarity of the wiring before the speaker system is flown A simple method of doing this without a pulse based polarity checker for LF units is as foll...

Страница 5: ...turers amplifiers in a single installation that the have very closely matched gains the variation should be less than 0 5dB This precaution is important to the overall system balance when only a singl...

Страница 6: ...undary is reflected As a result the sound pressure level can increase by as much as 3 dB effectively doubling the available amplifier power The loudspeaker is radiating its power into half as much spa...

Страница 7: ...9 Dimensions B950 160 0 450 0 125 0 145 0 2 HANDLES BOTH ENDS 576 0 650 0 1110 0...

Страница 8: ...10 Performance Data...

Страница 9: ...18mm multi ply birch plywood Finish Textured black grey paint Protective Grille Perforated steel black with 50 free air flow Connectors 2 x Speakon NL4MPR IN OUT Rigging Fittings 4 x Recessed carrying...

Страница 10: ...tal loudspeaker management system HK 220 240V 13 Warranty No maintenance of the B950 loudspeaker is necessary All Tannoy professional loudspeaker products are covered by a 5 year warranty from the dat...

Страница 11: ...ted such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate l...

Страница 12: ...99 Fax 44 0 1236 428230 Internet http www tannoy com TGI Tannoy 300 Gage Avenue Kitchener Ontario CANADA N2M 2C8 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijlstraat 19 3...