Tannoy B400 Скачать руководство пользователя страница 4

For a worldwide list of distributors, please contact Neutrik directly: -

N

EUTRIK

 AG:

+41 7529666

Cable choice consists mainly of selecting the correct cross sectional area in relation
to the cable length and the load impedance. A small cross sectional area would
increase the cables series resistance, inducing power loss and response variations
(damping factor).

Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This
will be perfectly satisfactory under normal conditions. In the case of very long cable
runs the wire size should exceed this, refer to the following table for guidance:-

CABLE RUN
(m)

C.S.A. OF EACH
CONDUCTOR (mm)

CABLE
RESISTANCE 

% POWER LOSS
INTO 8

 LOAD

% POWER LOSS
INTO 4

 LOAD

10

2.5
4.0
6.0

0.14
0.09
0.06

1.7
1.1
0.73

3.5
2.2
1.5

25

2.5
4.0
6.0

0.35
0.22
0.14

4.3
2.7
1.8

8.6
5.4
3.6

50

2.5
4.0
6.0

0.69
0.43
0.29

8.6
5.4
3.6

17.0
11.0
7.2

100

2.5
4.0
6.0

1.38
0.86
0.58

17.0
11.0
7.2

35.0
22.0
14.0

4. Polarity Checking

It is most important to check the polarity of the wiring before the speaker system is
flown. A simple method of doing this without a pulse based polarity checker for LF
units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery.
Apply the wire, which is connected to the +ve terminal of the battery to the speaker
cable leg, which you believe to be connected to pin 1+ of the speaker connector and
likewise the -ve leg of the battery to pin 1-.

If you have wired it correctly the LF drive unit will move forward, indicating the wiring
is correct. All that remains now is to connect the +ve speaker lead to the +ve
terminal on the amplifier and the -ve lead to the -ve terminal on the amplifier. If
however the LF driver moves backwards, the input connections need to be inverted.

If problems are encountered, inspect the cable wiring in the first instance. It should
also be noted that different amplifier manufacturers utilise different pin configurations
and polarity conventions, if you are using amplifiers from more than one
manufacturer, check the polarity at the amplifiers as well as the loudspeakers.

Содержание B400

Страница 1: ...B400 USER MANUAL...

Страница 2: ...ling 4 Polarity Checking 5 Amplification Power Handling 6 Crossovers 7 Equalisation 8 Positioning 9 Dimensions 10 Rigging 11 Performance Data 12 Technical Specifications 13 Recommended Service Parts A...

Страница 3: ...he air and by using 35mm tubing a tripod can be eliminated 2 Unpacking Every Tannoy product is carefully inspected before packing After unpacking your B400 please inspect for any exterior physical dam...

Страница 4: ...larity Checking It is most important to check the polarity of the wiring before the speaker system is flown A simple method of doing this without a pulse based polarity checker for LF units is as foll...

Страница 5: ...dB This precaution is important to the overall system balance when only a single active crossover is being used with multiple cabinets it is therefore recommended that the same amplifiers are used thr...

Страница 6: ...undary is reflected As a result the sound pressure level can increase by as much as 3 dB effectively doubling the available amplifier power The loudspeaker is radiating its power into half as much spa...

Страница 7: ...9 Dimensions 115 0 160 0 260 0 650 0 130 0 578 0 555 0 325 0 B400 365 0 330 0...

Страница 8: ...ficer before installing any Superdual series product Alternatively check all relevant laws or bylaws The B400 utilises MAN Rigging accessories This easy to use system combines flexibility with the hig...

Страница 9: ...11 Performance Data...

Страница 10: ...Finish Textured black grey paint Protective Grille Perforated steel black with 50 free air flow Connectors 2 x Speakon NL4MPR IN OUT Rigging Fittings 2 x Recessed carrying handles 1 x 35mm Pole Mounti...

Страница 11: ...0732 Tannoy TDX1 Digital loudspeaker management system HK 220 240V 14 Warranty No maintenance of the B400 loudspeaker is necessary All Tannoy professional loudspeaker products are covered by a 5 year...

Страница 12: ...ed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate le...

Страница 13: ...99 Fax 44 0 1236 428230 Internet http www tannoy com TGI Tannoy 300 Gage Avenue Kitchener Ontario CANADA N2M 2C8 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijlstraat 19 3...

Отзывы: