Tannoy 1200 Скачать руководство пользователя страница 3

results the monitors should be mounted on a rigid structure, supported on pads
making contact with the laminated panel. Self-adhesive foam pads are provided with
the loudspeakers for that purpose. If you intend to arrange the monitors in landscape
format, detach the whole pad from the backing paper and stick it on the large side to
become the bottom of the cabinet ; for portrait arrangement the pad is pre-cut so that
one half can be easily detached to match the smaller size of the bottom panel.

We recommend location of the monitors so that the drive units are toed inwards, with
their axes oriented towards the listening position. The distance between the two
speakers should be 2 to 3 metres, depending on the monitoring position. The
distance between the monitoring position and each speaker should be slightly greater
than the distance between the speakers. If the speakers are placed too close to each
other the full stereo image may not develop, on the other hand if you place them too
far apart you will notice a hole in the middle of the stereo image.

Ensure that the console position does not obscure the direct sound radiation from the
Dual Concentric drive unit when sitting down. The engineer and producer should
have a clear, uninterrupted view of the monitor loudspeakers.

Connecting the loudspeakers.

The loudspeaker can be connected to the amplifier via to two different modes of
operation : conventional wiring and bi-wiring. In the latter mode two separate pairs of
cables are used to connect the amplifier to the monitor, i.e. one for the low-frequency
(LF) and one for the high-frequency (HF) sections.

The termination panels located at the back of the loudspeakers must be set
according to the desired wiring mode, as shown on the figures below. The
termination panels are factory set for normal wiring operation, as shown on Fig.1. In
this mode the LF and HF banana sockets are connected together by two gold-plated
links, allowing a single twin core cable to drive the loudspeaker. For bi-wiring
operation, loosen the banana sockets (turn knob anti-clockwise) and remove the two
gold-plated links ; then connect each twin core cable to one pair of red / black
terminals of the speaker (one is marked LF and the other HF), as shown on Fig. 2. At
the other end (amplifier) the two cables are connected together, positive to positive,
negative to negative.

Figure 1. Normal wiring

Figure 2. Bi-wiring

When connecting the speakers it is essential that consistent polarity is observed. The
red terminal(s) on the loudspeaker must be connected to the red or positive
terminal(s) on the power amplifier, and the black terminal(s) on the loudspeaker must
be connected to the black, negative or ground terminal(s) of the power amplifier.

Содержание 1200

Страница 1: ...REFERENCE MONITORS SYSTEM 1200 USER MANUAL ...

Страница 2: ...floor and lift the carton vertically up to leave the speaker resting on its packing tray Inspect each speaker for signs of transit damage In the unlikely event of this having occurred inform the carrier and the supplier Keep all the packaging if damage has occurred as this will show evidence of excessive handling forces It is also a good idea to keep the carton for future transportation Preliminar...

Страница 3: ...of the monitor loudspeakers Connecting the loudspeakers The loudspeaker can be connected to the amplifier via to two different modes of operation conventional wiring and bi wiring In the latter mode two separate pairs of cables are used to connect the amplifier to the monitor i e one for the low frequency LF and one for the high frequency HF sections The termination panels located at the back of t...

Страница 4: ...e all interdependent Drive unit The drive unit used in the System 1200 monitors is part of the latest generation of Dual Concentric units designed by Tannoy Among many others features this range of drivers incorporate a dual magnet assembly tulip HF waveguide and injection moulded polypropylene LF cone The design of the HF waveguide has been arrived at by making extensive use of CAD computer aided...

Страница 5: ...uency areas In that respect conventional rectangular sharp corner boxes perform especially poorly On the other hand the shape of the System 1200 has been designed with careful attention paid regarding the sculptured front panel to provide smooth rounded edges which minimise side diffractions Another problem involved in cabinet design is to ensure that the box will effectively behave as neutrally a...

Страница 6: ...e will change colour when wet but will return to normal when dry For touch up of paint chips contact your local Tannoy service agent for materials and guidance Dual Concentric driver removal Lay the cabinet on its back Remove the four hexagonal bolts and set aside Ease the driver from the front of the cabinet taking care not to mark the front surface Use a piece of stout cardboard to lever against...

Страница 7: ...er at higher levels is permissible provided that the lower frequency of the sweep is limited according to the voltage level for instance with levels exceeding 10V rms the frequency should be kept above 100 Hz List of spare parts PART NUMBER DESCRIPTION 9900 0314 System 1200 cabinet assembly 7900 0459 Driver kit 3139 7900 0460 Recone kit for LF unit 7900 0199 HF diaphragm assembly 6839 0050 Gasket ...

Страница 8: ...DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION This warranty in no way affects your statutory rights ...

Страница 9: ...CURVES Figure 1 On axis anechoic response Figure 2 Impedance ...

Страница 10: ...mensions HxWxD 650 mm x 397 mm x 396 mm Cabinet weight 27 kg Shipping dimensions HxWxD 720 mm x 467 mm x 472 mm Shipping weight 30 kg NOTES 1 3 dB measured at 1m in an anechoic chamber 2 Long term power handling capacity as defined in EIA standard RS426A 3 Averaged over specified bandwith for half space environment For anechoic conditions the figure is to be decreased by 3 dB Tannoy operate a poli...

Страница 11: ... such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended Details of the Apparatus Tannoy Monitor Loudspeaker Model Number System 1200 Associated Technical F...

Страница 12: ...ephone 44 0 1236 420199 Fax 44 0 1236 428230 Internet http www tannoy com Tannoy North America Inc 335 Gage Avenue Suite 1 Kitchener Ontario CANADA N2M 5E1 Telephone 519 745 1158 Fax 519 745 2364 Tannoy Nederland BV Anthonetta Kuijlstraat 19 3066 GS Rotterdam THE NETHERLANDS Telephone 010 2860554 Fax 010 2860431 Issue 2 Part No 6481 0282 ...