PROV APPLICATOR MAINTENANCE

O-RING SEAL

FLUID

NOZZLE

ADJUSTABLE 

NOZZLE

RETAINING

RING

TROUBLESHOOTING - BLOCKED NOZZLE OR CONTINUOUS SPRAY WITHOUT PRESSING THE TRIGGER 

STEP 1 - 

Locate and unscrew retaining ring. To release; turn retaining ring in an anti-clockwise motion.  

STEP 2 - 

Gently pull on the adjustable nozzle to remove.

STEP 3 - 

Gently remove the metal disc and spring.

STEP 4 - 

Fit an 8mm spanner to the flat edges of the fluid nozzle and turn anti-clockwise to unscrew.

STEP 5 - 

Ensure you do not misplace the o-ring seal, which is located behind the fluid nozzle .

STEP 6 - 

Once removed, visually inspect the fluid nozzle for small particles or blockages -  

 

  rinse thoroughly with hot water.

STEP 7 - 

Gently wipe the fluid needle to clean and remove any debris.  (the fluid needle should not be  

                removed from the applicator at any time)

STEP 8 - 

Once visually clear of any debris, re-attach fluid nozzle, ensuring the O-ring is in position, then  

 

  use the spanner 

(8mm) 

to gently tighten back into place.

STEP 9 - 

Replace spring, then gently insert metal disc ensuring the grooves on the disc line up with the  

 

  sides and the raised front is forward facing.

STEP 10 - 

Replace adjustable nozzle and rotate back into position.

STEP 11 -

 Repeat previous step, this time with the retaining ring.

FLUID

NEEDLE

METAL

DISC

SPRING