TankScan TSM1000 Скачать руководство пользователя страница 2

ATEK Access Technologies

10025 Valley View Road, Ste. 190 
Eden Prairie, MN 55344 U.S.A. 

PH:   1.800.523.6996 
FAX:  1.800.589.3705

+1.218.829.9797

www.atekaccess.com

©2021 ATEK Access Technologies, LLC. All Rights Reserved. TankScan images and marketing materials are protected by various patents, copyrights 

and/or trademarks. ATEK assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or 

specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to 

patents or other intellectual property of ATEK are granted by the Company in connection with the sale of TankScan products, expressly or by implication.

223-0191-000  Rev. B  

6

/21

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

12

11

7

For monitors installed on risers greater than 3” long, a PWG is required to 
prevent probe wire from contacting riser. Refer to TankScan Probe Wire 
Guard Installation Guide or tankscan.com/support.

NOTE

Return to these setup instructions to complete monitor 

installation after Probe Wire Guard installation.

If PWG is required but not provided as a field-installable kit, contact 
TankScan Technical Support to order PWG Field Install Kit before proceeding. 

If PWG is not required, then proceed to step 8.

Determine if Probe Wire Guard (PWG) is Needed

8

9

Lower probe wire with weight gently through tank port into tank. Position 
monitor over tank port and hand tighten until secure.

Seal pipe threads of monitor using product appropriate for this application 
prior to tightening into tank port. Remote battery pack cable can be removed 
for ease of installation then plugged in once monitor is fully mounted.

Connect battery cable to remote battery pack and mount remote battery 
pack at base of tank such that the battery cable is coming out bottom of 
remote battery pack housing. If mounting remote battery pack to a plastic 
tank, apply hook and loop fastener strips to edges of magnet face of remote 
battery pack. 

Mount TSM Monitor to Tank

10

Test monitor by swiping magnet end of supplied screwdriver along cover’s 
rim above triangle indicator on housing base until a beep is heard. Monitor 
will take a level reading and then report to ATEK Intelligence Platform (AIP). 
A second single beep will occur once monitor has finished reporting its 
level measurement.  

If monitor has been pre-provisioned, then confirm reading is correct on AIP 
or optionally call TankScan Technical Support, to finish or confirm reading.

NOTE: 

Step 12  must be completed for monitor to function properly.

Test Setup

TankScan Technical Support 

877-847-7226

[email protected]

7

TSM1000 Tank Monitor 

with 

Remote Battery Setup Instructions

10

12

Cellular

Contains FCC ID: MCQ-XB3M1
Contains IC: 1846A-XB3M1

Rf

Contains FCC ID: MCQ-XBEE3
Contains IC: MCQ-XBEE3

Operation is subject to the following 

2 conditions:

1. This device may not cause harmful

interference and

2. This device must accept any interference

received, including interference that may
cause undesirable operation.

Отзывы: