Installation requirements
Do not install the water heater in a bedroom, basement, bathroom, or any room with poor
ventilation. In order to keep the room for installation ventilated well, an air-intake hole
should be made in the lower area of the room, and the hole areas should not be less than
100cm
2
– (15 square inches)
(See combustion air requirements below)
The flame display window of the water heater should be located in a position where the
flame window can be easily viewed at eye level (approximately five feet above the floor)
No wires or electric equipment shall be put above the water heater. The heater should be
kept at least 15 inches away from electronics horizontally. The heater should be kept well
away from any flammable substance or liquid.
Do not install the water heater where adverse winds may blow, causing flame-out or
incomplete combustion.