 Positioning the Monitor

Place the measuring platform on a hard, flat surface where there is minimal vibration to 

ensure safe and accurate measurement.

Note:

 To avoid possible injury, do not step on the edge of the platform.

Handling Tips

This monitor is a precision instrument utilizing state-of-the-art technology.

To keep the unit in the best condition, follow these instructions carefully:

• Do not attempt to disassemble the measuring platform.

• Store the unit horizontally.

• Avoid excessive impact or vibration to the unit.

• Place the unit in an area free from direct sunlight, heating equipment, high humidity, or extreme temperature change.

• Never submerge in water. Use alcohol to clean the electrodes and glass cleaner (applied to a cloth first) to keep them shiny; avoid 

soaps.

• Do not step on the platform when wet.

• Do not drop any objects onto the platform.

• Do not use this scale while operating transmitters (such as a cell phone) as this may affect your results.

• If not in use for prolonged period of time it is recommended that you remove the batteries.

 Inserting the Batteries

Open the battery cover on the back of the measuring platform. Insert the supplied 

AA-batteries as indicated.

Note:

  Be sure that the polarity of the batteries is set properly. If the batteries are 

incorrectly positioned the fluid may leak and damage floors. If you do not intend to 

use this unit for a long period of time, it is advisable to remove the batteries before 

storage.

Please note that the included batteries from factory may have decreased energy levels over 

time.

Heels centered on

electrodes

Toes may overhang

measuring platform

Note:  

An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent or you are in a sitting 

position.

To ensure accuracy, readings should be taken without clothing and 

under consistent conditions of hydration. If you do not undress, 

always remove your socks or stockings, and be sure the soles of 

your feet are clean before stepping on the measuring platform.

Be sure that your heels are correctly aligned on the measuring 

platform. Don’t worry if your feet appear too large for the unit-

accurate readings can still be obtained if your toes overhang the 

platform.

It is best to take readings at the same time of day. Try to wait about 

three hours after rising, eating, or hard exercise before taking 

measurements.

While readings taken under other conditions may not have the same 

absolute values, they are accurate for determining the percentage of 

change as long as the readings are taken in a consistent manner. To 

monitor progress, compare weight and body fat percentage taken 

under the same conditions over a period of time.

PREPARATIONS BEFORE USE

GETTING ACCURATE READINGS

Open as shown.

Direction of 

the batteries.

Содержание Ironman InnerScan BC-1500

Страница 1: ... this Instruction Manual carefully and keep it for future reference Ironman Ironman Triathlon and M dot are registered trademarks of World Triathlon Corporation Model BC 1500 Radio Wireless Segmental Body Composition Platform ...

Страница 2: ...be lost if the monitor is used incorrectly or is exposed to electrical power surges Tanita takes no responsibility for any kind of loss caused by the loss of recorded data Tanita takes no responsibility for any kind of damage or loss caused by the monitor or any kind of claim made by a third person Important Notes for Users This Body fat monitor is intended for adults and children ages 7 17 with i...

Страница 3: ...tioned the fluid may leak and damage floors If you do not intend to use this unit for a long period of time it is advisable to remove the batteries before storage Please note that the included batteries from factory may have decreased energy levels over time Heels centered on electrodes Toes may overhang measuring platform Note An accurate reading will not be possible if the soles of your feet are...

Страница 4: ...een after pairing is complete Your platform is now paired with your PC 7 For the measurement click New Measurement to use the platform directly from the Software Note Please grip the handle electrode as shown using a light firm pressure Place your hands on your side and do not move until measurement is completed Keep your arms straight up and down while making sure that you do not touch your legs ...

Страница 5: ... exceeded Weight capacity is 330lb 150kg Blinking Red Indicator Light Batteries are low When the Red Indicator Light is blinking replace the batteries immediately since weak batteries will affect the accuracy of your measurements Change all the batteries at the same time with new batteries Specifications Weight Capacity 330lb 150kg Weight Increments 0 2lb 0 1kg Power Supply DC 6V AA Battery LR6 4 ...

Страница 6: ...Hoogoorddreef 56 E 1101 BE Amsterdam The Netherlands Tel 31 20 560 2970 Fax 31 20 560 2988 www tanita eu TANITA India Private Limited TANITA Corporation of America Inc 2625 South Clearbrook Drive Arlington Heights IL 60005 USA Tel 1 847 640 9241 Fax 1 847 640 9261 www tanita com Manufacturer TANITA Corporation 1 14 2 Maeno Cho Itabashi ku Tokyo Japan 174 8630 Tel 81 3 3968 7048 Fax 81 3 3968 2661 ...

Отзывы: