background image

Please read this Instruction Manual carefully and keep it handy for future reference.

Temperature Range

:  

41 to 95°F/5 to 35°C

Relative Humidity Range

:  

30 to 80%

(without condensation)

Maximum Altitude

:  

6,500ft ASL/2,000m ASL

Atmospheric Pressure Range :  

86 to106kPa

Temperature Range

:  

14 to 140°F/-10 to 60°C

Relative Humidity Range

:  

10 to 90% 

(without condensation)

Atmospheric Pressure Range

:  

70 to 106kPa

<Storage/Transport Conditions>

<Usage Conditions>

To avoid malfunctions, avoid storing the equipment in a location that is 
subject to direct sunlight, significant temperature changes, dampness, large 
amounts of dust, the risk of vibration or impact, or near naked flames. 

Images in this manual are for illustrative purposes only.

DC-240

Body Composition Analyzer

Instruction Manual

Содержание DC-240

Страница 1: ... 140 F 10 to 60 C Relative Humidity Range 10 to 90 without condensation Atmospheric Pressure Range 70 to 106kPa Storage Transport Conditions Usage Conditions To avoid malfunctions avoid storing the equipment in a location that is subject to direct sunlight significant temperature changes dampness large amounts of dust the risk of vibration or impact or near naked flames Images in this manual are f...

Страница 2: ...pecifications 26 Intended Use Efficacy The TANITA body composition analyzer is a medical device intended to measure weight and impedance and to estimate body composition such as the body fat percentage total body water percentage muscle mass bone mass visceral fat rating basal metabolic rate BMR fat mass body mass index BMI and metabolic age using a noninvasive method on Bioelectrical Impedance An...

Страница 3: ...uct May result in fire No modification of this product is allowed There is a risk of electrocution or injury Nor can precise analysis be guaranteed Prohibited This product must not be used on subjects with pacemakers or other mechanical implants This product passes a weak electrical current through the body which could interfere with and cause the malfunction of electrical medical implants resulti...

Страница 4: ...bilities who may not be able to take a measurement alone For your safety to avoid the risk of electric shock and to secure the accuracy keep a clearance with patients during measuring Be sure to clean the scale platform with appropriate disinfectant after each use Continually monitor both the subject and the product for anomalies Should an anomaly with the subject or the product be discovered take...

Страница 5: ...Readings are greatly affected by the level of hydration and position of the body Please use at the same time each day under the same conditions and in the same body position Avoid measuring in multiple locations with greatly differing temperatures This may cause inaccurate measurements Allow the product to stand for at least 2 hours before using if it is moved to a new location with a temperature ...

Страница 6: ...mage or contamination All cables cords and connector ends for damage or contamination All safety related labeling for legibility All accessories sensors electrodes etc for wear or damage 3 Visually inspect the following at least monthly Update settings replace items or call for service as necessary according to the results of the visual inspections Do not use the unit if you see any signs of damag...

Страница 7: ...lay Front Back Scale side Floor side Correct direction Adjustable feet Platform Battery Box The correct direction of the adjustable feet Electrode If the adjustable feet came off attach these in the direction of the following figure The product will not work if attached incorrectly ...

Страница 8: ...Polarity of DC power connector Serial number For indoor use only NET Indicates that the clothes weight is input Step On Indicates that the measuring start Height Indicates that the height is input Age Indicates that the age is input Weight Lock Mode Indicates that the Weight Lock function is activated Weight Lock Indicates that the Weight is locking Weight Only Indicates that the Weight Only Scale...

Страница 9: ...st be used with the designated AC adapter Please observe the following instructions for accurate measurement Measurement may not be possible on the unstable environment During weight measurement please don t touch any connecting cable such as an AC Adapter cable and PC communication cable to avoid causing unstable scale installation Do not use old batteries together with new batteries or a mix of ...

Страница 10: ...en using the AC Adapter When using the batteries Press to turn on the power Press to turn off the power When turn off the power Pull out the batteries or AC adapter in case of an emergency For emergency keep clear around the outlet during operating this product ...

Страница 11: ... of the beep sound SET 0 Check the software version 0 off 1 on default 1 on SET 2 Set ON OFF of the athlete selection 0 off 1 on default 1 on SET 3 Set the automatic determination time when inputting input range 0 9 seconds default 5 seconds 0 automatic determination function deactivate SET 4 Set the automatic power off time 0 5 10 30 60 minutes default 5 minutes 0 automatic power off function dea...

Страница 12: ...w to Use Mode Selection 1 2 Model name is displayed is displayed The product will be booted by Body Composition Mode Select the mode by 3Press Body Composition Mode P 13 Scale Mode P 16 Scale Weight Lock Mode P 17 Scale BMI Mode P 18 ...

Страница 13: ...er 13 How to Use Body Composition Mode 2Check that the Body Composition Mode is selected P 12 3Input the clothes weight by using or 4Select the body type and gender by using or 1 è clear the input Press è clear the input Press ...

Страница 14: ...How to Use Body Composition Mode Continue 14 5 Input the height by using or 6 Input the age by using or è return to previous status Press è return to previous status Press ...

Страница 15: ...How to Use Body Composition Mode 15 7 8 Step on the platform with bare feet after Step On flashing Measurement completion Body fat Body weight BMI Total body water return to previous status è ...

Страница 16: ...ct the Scale Mode Check that the Weight Only lights up P 12 3Input the clothes weight by using or 1 4 5 Step on the platform after Step On flashing Measurement completion Press to turn on the power è return to previous status Press ...

Страница 17: ...ck that the Weight Only Weight Lock Mode lights up P 12 3 1 Activation of Weight Lock Mode 4 5Measurement completion è Clear the displayed result Input the clothes weight by using or Step on the platform after Step On flashing Press to turn on the power è clear the input Press ...

Страница 18: ... displayed P 12 3Input the clothes weight by using or 4 1 Input the height weight by using or 5 6 Step on the platform after Step On flashing Measurement completion Press to turn on the power è Clear the displayed result è clear the input Press è return to previous status Press ...

Страница 19: ...information Nothing is displayed even after turning on the power is displayed Check that the power supply is connected correctly The weight to measure exceeds the measurement range If the soles of your feet are dry use a dropper to drop about 0 5mL of water on the electrodes before measurement Turn off the power and remove the items on the platform and turn on the power again and then redo the mea...

Страница 20: ...er TBW deuterium oxide D2O is generally used as the labeled substance Deuterium oxide uses the overall total body water as dilution space so the total body water can be obtained To obtain the extracellular fluid amount sodium bromide NaBr is used as a labeled substance Bromine Br is said to not enter the inside of cells and uses extracellular fluid as the dilution space Body composition measuremen...

Страница 21: ...e you fall within the Body Fat Ranges for your age and gender What is body fat percentage Body fat percentage is the amount of body fat as a proportion of your body weight Healthy Range Indicator Overfat and Obese Overfat above the healthy range Increased risk for health problems Obese high above the healthy body fat range Greatly increased risk of obesity related health problems 0 Healthy within ...

Страница 22: ... dehydrated after a long night and there are differences in fluid distribution between day and night Eating large meals drinking alcohol menstruation illness exercising and bathing may cause variations in your hydration levels Your body water percentage reading should act as a guide and should not be used to specifically determine your absolute recommended total body water percentage It is importa...

Страница 23: ...ease the amount of body fat A low basal metabolic rate will make it harder to lose body fat and overall weight The basic way of calculating Basal Metabolic Rate BMR is a standard equation using weight and age TANITA has conducted in depth research into the relationship of BMR and body composition giving a much more accurate and personalized reading for the user based on the impedance measurement T...

Страница 24: ... of bone masses by weight Source TANITA Body Weight Science Institute Please use the below charts as a guide to compare your bone mass reading What is muscle mass This feature indicates the weight of muscle in your body What is bone mass This feature indicates the amount of bone bone mineral level calcium or other minerals in the body Women Average of estimated dry bone mass Weight lb Less than 11...

Страница 25: ...uctions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reo...

Отзывы: