Output (Fat Monitor Mode) Format
쎱
Transmission Data
쎱
Control Commands
Remote Mode
All types of data may be entered by connecting the BF-350 to a PC and switching to Remote mode.
When in Remote mode, the body fat analyzer may be operated remotely by sending control commands from a host.
쎱
Error Codes
If an error occurs, the body composition analyzer will send an error code to the host.
쎱
Switching to Remote Mode
●
The receiving PC must be ready to accept output data immediately after
measurement is completed.
CAUTION
Output data
Byte Length
First byte
1
1
5
Second byte
K: unit of weight kg
L: unit of weight lb
S: stability of load (weight output)
D: instability of load (weight output)
I : overload status
---: negative weight output
Header
Weight
xxx.x
Output data format
¥
Terminal data are CR (ASCII format: 0DH), LF (ASCII format: 0AH).
¥
Measurement data will be sent in the format shown to the right:
x x x x x . x
1. When the unit is switched off, press the [
]
and [
] keys simultaneously.
Note
The default setting is off.
2. Press [0], [8].
3. Switch Remote mode on and off by pressing [1]
or [0].
[1] :
Enables Remote mode
[0] :
Disables Remote mode
4. Press [
] to confirm.
Only "r S" will appear (standby screen).
Note
To switch off Remote mode, start
from the beginning again and
select "OFF" at Step 3.
ATHLETIC
STEP ON
FEMALE
MALE
kg
cm / ft.in
STABILIZED
AGE
% FAT
P T
ATHLETIC
STEP ON
FEMALE
MALE
kg
cm / ft.in
STABILIZED
AGE
% FAT
P T
ATHLETIC
STEP ON
FEMALE
MALE
kg
cm / ft.in
STABILIZED
AGE
% FAT
P T
ATHLETIC
STEP ON
FEMALE
MALE
kg
cm / ft.in
STABILIZED
AGE
% FAT
P T
*All fixed-length data right aligned. Enter
for blanks.
0
U? : Confirm current setting
U0: Use cm/kg mode
U1: Use in/lb mode
LF
CR
1
U
LF
CR
0
U
LF
CR
?
U
commands
U
R? : Confirm current setting
R0: Select equation for Westerners
R1: Select equation for Orientals
LF
CR
1
R
LF
CR
0
R
LF
CR
?
R
commands
R
D? : Confirm current setting
D0 : Set clothing weight (5-byte fixed length)
D1 : Set gender male = 1 female = 2
D2 : Set body type standard = 0 athlete = 2
D3 : Set height (5-byte fixed length)
D4 : Set age (2-byte fixed length)
D6 : Set Target BF (2-byte fixed length)
LF
CR
X
X
6
D
LF
CR
X
X
4
D
LF
CR
X
X
X
X
X
3
D
LF
CR
X
2
D
LF
CR
X
1
D
LF
CR
X
.
X
X
X
0
D
LF
CR
?
D
commands
D
G1: Start measuring body fat
G2: Measure weight only
LF
CR
2
G
LF
CR
1
G
commands
G
CHR$(01FH): Reset settings
LF
CR
CHR$(01FH)
Special
commands
E00 : Attempted to start measuring without completing settings
E01 : Error in calculating body fat percentage
EXX :other error ’ body fat analyzer switches off
LF
CR
X
X
E
LF
CR
1
0
E
LF
CR
0
0
E
*See p.26 "7. Troubleshooting" for details of errors.