background image

The body fat function of the BF-572 can be operated only if personal
data (Adult/Athlete/Child, Female/Male and Height) has been 
preprogrammed into at least one of the four Personal Keys. 

1. Turn on the Power

When programming data, press

to turn the unit on (once pro-

grammed, tapping a Personal Key turns the unit on). The unit will
beep to confirm activation, the Personal Key numbers (“12 34”) will
be displayed, an arrow icon will appear in the lower right corner,
and the display will flash.

2. Select a Personal Key

Press

to select a Personal Key (pressing

once will activate

Personal Key number 1, pressing

twice will activate Key 

number 2, etc.). Once you reach the Personal Key number that you
wish to use, press 

. (During programming, the unit will beep

once each time you press 

.)

3. Select Adult, Athlete or Child Mode.

Use

to specify Adult, Athlete or Child, then press

.

Adult =  age 18 or older, who has moderately active to 

inactive lifestyle.

Child =  up to the age of 18, over 3' 4" (102 cm), who has

moderately active to inactive lifestyle.

Athlete =  adult involved in intense physical activity. (See p.1 for 

Tanita’s definition of “athlete.”)

4. Select Female or Male

Use

to select Female or Male, then press

.

5. Specify the Height

Use

to specify height (in feet and inches if weight mode is set 

to lbs or st-lb, or in centimeters if weight mode is set to kg). 
Then press

.

The unit will beep twice and the display will flash all data (Adult/
Athlete/Child, Female/Male and Height) for three seconds to confirm
the programming. The power will then automatically shut off.

Note: 

As you enter data, or while the display flashes the personal settings,

we recommend that you check for any mistakes, such as an incorrect
height setting. If you find that you have made a mistake, tap the Weight-Only
Key while the display is flashing. The unit will automatically shut off and
will cancel any data that you entered at that time. 

Reprogramming a Personal Key 

From time to time, you may need to adjust the data stored in a
Personal Key. 

• The most common need for this would be to allow a new user or a

guest to obtain readings, even though all four Personal Keys
already contain data.

– To add a new or guest user and erase the data of a previous user,

repeat the Steps 1 through 5 of Setting and Storing Personal
Data in Memory

. After you have entered the new data, “Clear”

will appear and flash on the display (the unit is asking if it is 
OK to delete the previous user’s data). Press 

once more.

“Clear” will be displayed for three seconds. The display will
then flash all the new data to confirm programming, and the
power will shut off automatically.

Warning: 

All previous data and readings for the previous user of the

selected Personal Key will be erased, including Graph data.

• You may also need to change your personal data if your height has

changed, or if you need to change the user mode for your readings
(from Adult to Athlete or vice versa, or when a teenager needs to
start using the Adult mode). In these cases you can reprogram a
Personal Key without erasing the data stored in the Graph.

– To make any of the above changes, repeat Steps 1 through 5, of

Setting and Storing Personal Data in Memory

. The unit will

beep, the display will flash the new data, and the unit will shut
off automatically. The previously stored Graph results for the
Personal Key will still be stored. 

Note: 

Graph readings will not remain stored if you reprogram a Personal

Key from Adult to Child, or try to change the gender. The previous readings
(for that reprogrammed Personal Key) stored in the Graph will be erased.

5

SET

Adult

SET

Adult Child

Athlete

SET

Adult

Female

SET

Adult

Male Female

SET

Adult

Female

Setting and Storing Personal Data in Memory

Instruction Manual (English)

Adult

Male Female Height

SET

Adult

Male Female Height

SET

Содержание BF-572

Страница 1: ...BF 572BODYFAT MONITOR SCALE Monitoring Your Health Instruction Manual Read this Instruction Manual carefully and keep it for future reference ...

Страница 2: ...s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guar...

Страница 3: ...uals who have been fit for years but currently exercise less than 10 hours per week Tanita s athlete definition does not include enthusiastic beginners who are making a real commitment to exercising at least 10 hours per week but whose bodies have not yet changed to require the Athlete mode Body fat percentage estimates may be slightly lower or higher for the following categories of people Adults ...

Страница 4: ...ke a body fat percentage reading at a con sistent time of day under consistent conditions Besides this basic cycle of fluctuations in the daily body fat readings variations may be caused by hydration changes in the body due to eating drinking menstruation illness exercising and bathing Daily body fat readings are unique to each person and depend upon one s lifestyle job and activities The graph be...

Страница 5: ...7 Personal Keys Start Switches Used to store personal data Adult Athlete Child Female Male and Height for up to four individuals 8 Weight Only Key Used for weight measurement only Display Icons Adult Mode Child Mode Male Female Height Athlete Mode Accessories 9 Support Feet 4 Only needed if unit is placed on carpet Do not use these feet on hard flooring 10 AA Size Batteries 4 Printed Material This...

Страница 6: ...mode will be automatically set to feet and inches Similarly if kilograms is selected height will be automatically set to centimeters Automatic Shut Down Function The automatic shut down function shuts off the power automatically in the following cases If you interrupt the measurement process The power will shut down automatically within 10 to 30 seconds depending upon the type of operation If an e...

Страница 7: ...ashing The unit will automatically shut off and will cancel any data that you entered at that time Reprogramming a Personal Key From time to time you may need to adjust the data stored in a Personal Key The most common need for this would be to allow a new user or a guest to obtain readings even though all four Personal Keys already contain data To add a new or guest user and erase the data of a p...

Страница 8: ...vals At the same time the unit will display a Graph that shows your progress level over time see Understanding the Graph Function Note Even if you step off the platform after all results are displayed the alternating display of body fat percentage and body weight will be repeat ed for 20 seconds The BF 572 will store each of your results automatically for tracking purposes It stores the values of ...

Страница 9: ...e Recent Results section the total number of readings stored is 84 After 84 Readings The oldest set of 28 readings are deleted every time an additional set of 28 readings are stored Value of Vertical Increments The Graph creates diagrams using three different Values of Vertical Increments 0 2 0 5 and 1 to accommodate the different lev els of change within each individual s body If the Value of Ver...

Страница 10: ... mind or begin this erasing process unintentionally stop the deletion of data by pressing the Weight Only Key before all the bars disappear The unit will automatically shut off and will not erase any data Taking Weight Measurement Only 1 Select Weight Only Key Using your toe tap the Weight Only Key to select weight measure ment After 2 or 3 seconds 88888 will appear in the display and then it will...

Страница 11: ...hile measuring Reading can not be obtained if the weight capacity 300 lb 136 kg 21 st 6 lb is exceeded Note If body fat percentage is more than 75 readings can not be obtained from the unit The display flashes no and a Personal Key number alter nately and X flashes in the Graph area This message is part of the BF 572 s built in memory protection feature which prevents individuals from taking readi...

Страница 12: ...nge the terms of this warranty If Product Is Defective or Needs Repair Do not return this product to the place of purchase doing so may delay the processing of your warranty claim Call Tanita at1 800 TANITA 8 to receive a Return Authorization Number before returning this product Include 12 50 for handling return postage and insurance to the facility listed below Proof of purchase must accompany th...

Страница 13: ... 07031 6189 71 Fax Tanita UK Ltd The Barn Philpots Close Yiewsley West Drayton Middlesex UB7 7RY UK 01895 438577 Phone 01895 438511 Fax Tanita France S A Villa Labrouste 68 Boulevard Bourdon 92200 Neuilly sur Seine France 01 55 24 99 99 Phone 01 55 24 98 68 Fax Monitoring Your Health Specifications BF 572 Weight Capacity 300 lb 136 kg 21 st 6 lb Weight Increments 0 2 lb 0 1 kg 0 2 lb Body Fat Incr...

Отзывы: