Tanita BF-562 Скачать руководство пользователя страница 7

GB

GB

Then “ooooo” will appear in
succession.

Until the “Body fat
percentage” is displayed on
the digital display, move as
little as possible and 

stand

straight.

Measurement is finished.

“Body weight” and the “Body
fat percentage” will be
displayed for about 
3 seconds. 
(Two short beeps will sound.)

The measurement will be
automatically recorded.

* If “NOT RECORDED” is

displayed, please measure
yourself again within 

one

minute

. (For details, please

refer to page 18.)

The BMI figure is displayed.

Note:

When measured in the

athlete-mode, the BMI figure
will not be displayed.

2

Start measurement.

Your body weight will be
displayed.

(A short beep will sound.)

15

Graphs are displayed and
then the unit will switch
off.

Use

After 

kg is displayed, 

0.0

be sure to stand on the
weighing platform barefoot
so that your heels touch the
center of the electrodes.

Step on the scale platform
berefoot.

The measurement range of the body fat percentage is
between 1.0% and 75.0%.
If the details are not stored in the memory...

e

Please refer to “Guest Mode:Measuring without pre-
set data” on page 20.

In order to save power, the power will be
automatically switched off after use. (The display
disappears.) This function also works in the
following cases.

When the button operations are stopped.

Although it depends on the operation concerned, the
power will be switched off after about 20 to 30 seconds

When about 30 seconds have passed without
you stepping on the scale platform after
“0.0” kg is displayed.

When you stepped off the scale platform
during the measurement.

When about 30 seconds have passed since
the graph was displayed.

Automatic Power Off Function

GB

GB

Memory key 
(for five individuals)

Personal

If the display box and the scale platform are not
firmly connected.

e

"

ERROR

" will be displayed and you cannot measure

yourself.

If the soles of your feet are not clean or you are not
standing on the scale platform correctly,

e

-----

" will be displayed and you may not be able to

measure yourself.

If the body fat percentage exceeds the range of
measurement,

e

----

" will be displayed and you cannot measure

yourself.

If you step on the scale platform before 

kg is

displayed,

e

Displays such as 

,

or 

, may

appear or the power will be switched off during
measurement.

-OL

-1.1

ERROR

0.0

Measure barefoot with clean, dry feet.

Stand up with your knees straight.

Ensure the insides of your thighs are not touching.

Place your heels correctly on the electrodes.

Remarks

When your data is 

memorised with “3”.

1

Press your “Personal”
Memory Key.

14

How to Measure 

(For Pre-set data)

Have you memorised your personal details?

Display

Front

electrode

Heel

electrode

First, the calendar is
displayed.

(A short beep will sound.)

Next, your date of
birth, height, gender
and the “Personal”
Memory Key are
displayed.

The display changes to

kg.

0.0

Points to Note

BF-562海外GB+D面付解除   ページ15

Содержание BF-562

Страница 1: ...Instruction Manual For Home Use Please note Improper use of this product could cause serious injury or damage to the product or other property Please read this manual carefully before use and keep aside for future reference BF 562GB解除 裏から3 ページ1 ...

Страница 2: ...he product You could slip or fall and suffer serious injury Disabled persons should not use the equipment unassisted Use a handrail or obtain the assistance of a nurse or carer If using a handrail the readings obtained will only provide a rough indication of the user s actual weight and body fat percentage CAUTION Indicates the possibility of injury or damage to equipment if instructions are ignor...

Страница 3: ...box cover on the back of the display box insert the hooks of the large bracket into the holes on the bottom to attach the display box Always use the attached screws to attach the bracket for wall installation If you attach the bracket with double sided sticking tape for example it may fall down Ensure that the display box is firmly hooked on the bracket for wall installation If the display box is ...

Страница 4: ... time is wrong please correct it See How to change the calendar on page 21 When is displayed please set the calendar See Calendar Setting on page 10 Time DOWN Locate the battery compartment behind the display box open the battery box cover put in the AA R6P dry cell batteries Included Loading the batteries U When flashes for a few seconds and then disappears Lo When nothing is displayed When is di...

Страница 5: ...if the calender is not set Points to Note Automatic Power Off Function In order to save power the unit will automatically switch off after use The display disappears The automatic power off function also works in the following case When the button operations are stopped Although it depends on the operation concerned the power will be switched off after about 20 to 30 seconds If you have made a mis...

Страница 6: ...ation takes you back to the registration of your birthday please start the registration again In order to register with another number eAfter the display disappears please start over again When you want to change memorised data for another individual s data ePlease refer to Correction and Alteration of Personal Data on page 22 Personal GRAPH The display shows as right and the number blinks Persona...

Страница 7: ...e power will be switched off after about 20 to 30 seconds When about 30 seconds have passed without you stepping on the scale platform after 0 0 kg is displayed When you stepped off the scale platform during the measurement When about 30 seconds have passed since the graph was displayed Automatic Power Off Function GB GB Memory key for five individuals Personal If the display box and the scale pla...

Страница 8: ...ge This product was researched and developed using bioelectrical impedance analysis BIA which is a method of determining body fat percentage by measuring the body s electrical resistance Fat in the body conducts hardly any electricity whereas the water contained in muscles is a good conductor of electricity Measuring electrical resistance thus offers a way of determining the proportion of fat and ...

Страница 9: ...ECORDED is displayed for the first time press your Memory Key again within one minute Measure yourself Personal The BMI is displayed followed by the graphs and the power is switched off When NOT RECORDED Is Displayed While recording the results of your measurement sometimes NOT RECORDED is displayed and you cannot record the data Ensure that you use your own Memory Key Personal 1 4 When NOT RECORD...

Страница 10: ...st profits or any claims by a third party arising from the use of this equipment SELECT YOUR NO will be displayed and the Memory Key will blink Personal Remarks If NO DATA is displayed eMeasurements were not recorded at the time to which the cursor is pointing This is not a malfunction The displayed figures are weekly and monthly averages When you want to end the graph display function ePress butt...

Страница 11: ...the scale platform barefoot so that your heels touch the center of the electrodes After kg is displayed 0 0 2 To Start Measuring Measurement is finished your body weight and the Body Fat Percentage will be displayed for about three seconds Two short beeps will sound The BMI figure is displayed The unit will switch off Note When measured in the athlete mode the BMI figure will not be displayed Pres...

Страница 12: ...n before altering the pre recorded data 2 Altering the pre set details Following the displayed instructions alter the data See Before Measurement Registration of Personal Data on page 14 for details To enter corrections for body type Adult Athlete Height etc e g To change the height data as a child grows The measurement results recorded against the Memory Key will not be deleted Personal When alte...

Страница 13: ...eshooting RefertoPage Recorded Measurements Exchanging your Memory Key for another individual s Memory Key Personal Personal Exchanging another individual s Memory Key for your Memory Key Personal Personal Altering the date of birth year month day pre set against a Memory Key Personal Altering the gender male female pre set against a Memory Key Personal s Correcting the body type athlete pre set a...

Страница 14: ...m increments Power Source AA Dry Cell Batteries R6P x 4 Power Consumption DC6V Maximum 60mA Specifications This product is not legal for trade Points to Note Instructions for registration of date of birth You can register dates of birth for individuals aged from one to 90 years For individuals aged 91 years or older register the birthday so that he she is 90 years old For individuals aged six or y...

Отзывы: