- What is basal metabolic rate (BMR)?

WHAT IS BMR?

Your Basal Metabolic Rate(BMR) is the minimum level of energy your body needs when at rest to
function effectively including your respiratory and circulatory organs, neural system, liver, kidneys, and
other organs. You burn calories when sleeping.

About 70% of calories consumed every day are used for your basal metabolism. In addition, energy is
used when doing any kind of activity however; the more vigorous the activity is the more calories are
burned. This is because skeletal muscle (which accounts for approximately 40% of your body weight)
acts as your metabolic engine and uses a large amount of energy. Your basal metabolism is greatly
affected by the quantity of muscles you have, therefor increasing your muscle mass will help increase
your basal metabolism.

By studying healthy individuals, scientists have found that as people age, their metabolic rate changes.
Basal metabolism rises as a child matures. After a peak at the age of 16 or 17, it typically starts to
decrease gradually.

Having a higher basal metabolism will increase the number of calories used and help to decrease the
amount of body fat. A low basal metabolic rate will make it harder to lose body fat and overall weight.

HOW DOES A TANITA BODY COMPOSITION MONITOR CALCULATE BMR?

The basic way of calculating Basal Metabolic Rate BMR is a standard equation using weight and age.
Tanita has conducted in-depth research into the relationship of BMR and body composition giving a
much more accurate and personalized reading for the user based on the impedance measurement. This
method has been medically validated using indirect calorimetry (measuring the breath composition).*

* Reliability on equation for Basal Metabolic Rate: At 2002 Nutrition Week : A Scientific and Clinical Forum and Exposition Title:

International Comparison: Resting Energy Expenditure Prediction Models: The American Journal of Clinical Nutrition

-

WHAT IS METABOLIC AGE?

This feature calculates your BMR and indicates the average age associated with that type of
metabolism. 

If your BMR Age is higher than your actual age, it is an indication that you need to

improve your metabolic rate. Increased exercise will build healthy muscle tissue, which will improve
your metabolic age.

You will obtain a reading between 12 and 50. Under 12 will be displayed as “12” and over 50 displayed
as “50”.

- WHAT IS MUSCLE MASS?

This feature indicates the weight of muscle in your body. the muscle mass displayed includes the skeletal
muscles, smooth muscles (such as cardiac and digestive muscles) and the water contained in these
muscles.
Muscles play an important role as they act as an engine in consuming energy. As your muscle mass
increase, your energy consumption increases helping you reduce excess body fat levels and lose weight
in a healthy way.

- What is physique rating?

This feature assesses your physique according to the ratio of body fat ad muscle mass in your body.
As you become more active and reduce the amount of body fat, your physique rating will also change
accordingly. Even though your weight may not change, your muscle mass and body fat levels may be
changing making you healthier and at lower risk of certain diseases.
Each person should set their own goal of which physique they would like and follow a diet and fitness
program to meet that goal.

Содержание BC-420MA

Страница 1: ...GB REMOTE DISPLAY VERSION COLUMN MOUNTED VERSION Please read this Instruction Manual carefully and keep it handy for future reference BODY COMPOSITION ANALYZER BC 420MA Instruction manual ...

Страница 2: ...reening of certain adult diseases and conditions related body weight and composition It can be used in the monitoring and prevention of conditions caused by excessive deposits of fat tissue such as diabetes hyperlipidemia cholelithiasis and fatty liver It can be used in the monitoring of changes in individualsÅf body composition related to differences in the ratio of fat tissue to lean It can be u...

Страница 3: ...Before use cautions for safety Before use cautions for safety GB GB 5 4 ...

Страница 4: ...he machine as level as possible Rotate the adjustable feet in 4 positions for adjustment so that the bubbles of the level gauge reach the centre RED Air bubble In the state that the level gauge is viewed from the top Level gauge check Adjustable feet 4 positions Electrode 4 positions Level gauge Platform Syringe 1 item Instruction manual This manual Operation guide AC adapter AC cord Hexagonal wre...

Страница 5: ...f Plugs Control panel Rear side of the controller AC adapter To avoid electric shock do not insert or remove the plug with wet hands To avoid electric shock do not use the equipment near water To avoid measurement error do not measure while using equipment that generates radio waves such as mobile phones Use only the original AC adapter MODEL SA165 0950U 3 Using AC adapters other than the original...

Страница 6: ...MI page 22 Total body water page 22 48 Bone mass page 22 50 BMR page 22 51 Metabolic age page 22 52 Visceral fat rating page 22 54 The Rohrer s index page 22 55 Ideal body weight page 22 56 Degree of obesity page 22 57 Desirable range Body fat page 22 58 Graph Fat page 22 59 Graph BMI page 22 1 Date and time page 12 2 Number of sheets to print Body composition mode page 13 3 Number of sheets to pr...

Страница 7: ...d then press The number of sheets to print for the scale setting screen is displayed Enter Next 3 5 After inputting the numeric value press It returns to the setting item selection screen Enter Next Various settings Setting methods continued Note When various settings are continuously carried out epress each number to set The set contents are memorized until they are changed next time When various...

Страница 8: ... on 1 on for valid 0 off for invalid To correct the input value or cancel the input epress the input is deleted CE Press and then press The ON or OFF of the BMI display selection screen is displayed Enter Next 6 5 After inputting the numeric value press It returns to the setting item selection screen Enter Next Set with or without an ID Continued from page 10 3 4 Set with or without an ID The defa...

Страница 9: ... input unit of height The default is 1 on 0 off sets 0 1 cm unit input 1 on sets 1 cm unit input To correct the input value or cancel the input epress the input is deleted CE Press and then press The input unit of height selection screen is displayed Enter Next 0 1 5 After inputting the numeric value press It returns to the setting item selection screen Enter Next Set the automatic determination t...

Страница 10: ... print item preset Set with 3 1 The print items preset are ea function to set the print items of the pattern 1 3 to ON automatically at once page 19 The default is 1 pattern 1 When ON or OFF of print items are changed with the setting of the print out item after the print out preset page 22 the state set for the last time is valid Press and then press The print out preset setting screen is display...

Страница 11: ...ody weight FFM Fat Free Mass is comprised of muscle bone tissue water and all other fat free mass in the body TBW Total Body Water is the amount of water retained in the body TBW is said to comprise between 50 70 of total body weight Generally men tend to have higher water weight than women due to a greater amount of muscle Bone mass Bone mineral amount included in the entire bone Metabolic age Me...

Страница 12: ...e setting item selection screen Enter Next In the case of selecting 39 In the case of selecting the logo setting on 39 TANITA Logo 40 Category name 41 Serial number 42 Memo space 43 ID No 44 Fat mass 45 Fat free mass 46 Date 47 Muscle mass Visceral fat rating Total body water 48 Total body water 49 Bone mass 50 Basal metabolic rate BMR 51 53 BMI 54 Rohrer s index 55 Ideal body weight 56 Degree of ...

Страница 13: ...is 5 99 years old Input age 99 for those who are 100 years old or older Attention 25 24 3 Press to turn on the power 1 Press Enter Next The step on lamp flashes When is pressed it returns to the previous screen CE Note Check that the body composition monitor is selected and input the clothes weight Input it by pressing and The clothes weight preset tare can be input in the range of 0 0 10 0 kg To ...

Страница 14: ... selected with the numeric keys If it is mistakenly input epress the input is deleted and it returns to the body type selection screen If is pressed in the state that the body type is not input it returns to the ID number input screen or measurement start screen CE CE 2 1 Note 8 Select gender Press the male female selection keys to input When male or female is selected the lamp flashes on the Age ...

Страница 15: ... to the measurement start screen s How to read the display Judgment result based on the body fat percentage page 37 9 Input the age Input it by pressing The age can be input from 5 99 If it is mistakenly input epress the input is deleted If is pressed in the state that the age is not input it returns to the gender selection screen CE CE Note 9 0 10 Press When the age is input the lamp flashes on t...

Страница 16: ...input it returns to the ID number input screen or measurement start screen CE CE 2 1 Note 6 Select gender Press the male female selection keys to input When male or female is selected the lamp flashes on the Age If it is mistakenly input epress the input is deleted and it returns to the gender selection screen If is pressed in the state that the male or female is not selected it returns to the bod...

Страница 17: ...ng with or without an ID page 15 Note s How to read the display Judgment result based on the body fat percentage page 37 How to use cautions for safety GB 32 7 Input the age Input it by pressing The age can be input from 5 99 If it is mistakenly input epress the input is deleted If is pressed in the state that the age is not input it returns to the gender selection screen CE CE Note 9 0 8 Press Wh...

Страница 18: ...safety GB Operating Instructions Target body fat ratio Input the target body fat ratio Input it by pressing This screen is displayed if ON is set in the setting ON or OFF of the target body fat ratio The target body fat ratio can be input from 4 55 If it is mistakenly input epress the input is deleted If the number of sheet to print is set to 0 target body fat ratio setting function will be OFF au...

Страница 19: ...his screen is not displayed in the case that OFF is set in the setting with or without an ID page 15 The ID number can be input from 0 9999999999 If it is mistakenly input epress the input is deleted If is pressed in the state that an ID number is not input it returns to the measurement start CE CE Note 9 0 5 Press This screen is not displayed in the case that OFF is set in the setting with or wit...

Страница 20: ...ody water percentage reading should act as a guide and should not be used to specifically determine your absolute recommended total body water percentage It is important to look for long term changes in total body water percentage and maintain a consistent healthy total body water percentage Drinking a large quantity of water in one sitting will not instantly change your water level In fact it wil...

Страница 21: ...zed reading for the user based on the impedance measurement This method has been medically validated using indirect calorimetry measuring the breath composition Reliability on equation for Basal Metabolic Rate At 2002 Nutrition Week A Scientific and Clinical Forum and Exposition Title International Comparison Resting Energy Expenditure Prediction Models The American Journal of Clinical Nutrition W...

Страница 22: ...nything caught in the gaps The measured weight is not stable The paper comes out however nothing has been printed Troubleshooting Symptom Please check Please check the following before asking for repair Turn off the power and remove the items on the platform and turn on the power again and then redo the measurement How to measure Zero point error Impedance measurement error Measure with bare feet ...

Страница 23: ... Communication method Signal speed Data bit length Parity Stop bit Flow control Terminator Compatible with EIA RS 232C Asynchronous communication method 9600 bps 8 bits NONE 1 bit NONE CR LF BC 420MA conforms to the IEC60601 1 safety standard If you connect it to a computer please connect it to one that conforms to IEC60950 The RS 232C interface enables input and output from this equipment This eq...

Страница 24: ... of decimals unit cm 3 4 byte variable length to 1 place of decimals unit kg Weight Body fat Wk FW XXX X XX X 3 5 byte variable length to 1 place of decimals unit kg 3 4 byte variable length to 1 place of decimals unit Fat mass Fat free mass fW MW XXX X XXX X 3 5 byte variable length to 1 place of decimals unit kg 3 5 byte variable length to 1 place of decimals unit kg Muscle mass Muscle score mW ...

Страница 25: ...m the electrodes on the tips of the toes of both feet and voltage is measured on the heel of both feet The current flows into the upper limbs or lower limbs depending on the body part s to be measured Visceral adipose tissue VAT is fat that accumulates in the abdominal cavity and around internal organs VAT is said to be more likely to cause lifestyle related diseases than subcutaneous adipose tiss...

Страница 26: ...ng on the type and rigorousness of the exercise 4 If possible urinate before taking measurement 5 For repeated measurements measure at the same hour as much as possible At the same time of measurement of weight the measurements can be made more stable by measuring at the same time of the day Very stable measured values can be obtained by measuring under the above conditions And in the development ...

Страница 27: ...Fat Free Mass FFM than by the body weight Persons of a given body weight with a higher FFM will have a higher BMR and that from the aspect of evaluating the body composition should be estimated from the FFM In addition in cases of simple estimation formulae which can calculate from the height weight and age without evaluating the body composition there was a problem with excessively high evaluatio...

Страница 28: ...kg increments 3 75 0 1 increments 0 1 kg increments 0 1 kg increments 0 1 kg increments 0 1 kg increments 15 85 0 1 increments 0 1 kg increments 1 kJ increments 1 kcal increments 1 years increments 12 90 years 1 Level increments 1 59 Level 0 1 increments 0 1 kg increments 3 75 0 1 increments 150 1200Ω 3 Rows 5 Digits LCD RS 232C D sub 9 pins Female Connector or USB 0 35 C 30 80 without condensatio...

Страница 29: ...Copyright 2005 TANITA Corporation All Rights Reserved GB ...

Отзывы: