element User Manual v1.17 rev2  

 

 

 

13 

see the trouble shooting section on 

I don’t get the splash screen when I plug the 

panel in

 

15.7 I don’t get the splash screen when I plug the panel in 

 

If the display is similar to this this then 

your panel is in test mode. Just run 

your application as normal and the 

panel will continue to work as normal. 

 

 

 

If the display is similar to  this  then 

your panel is in update mode. You will 

have entered this because you have 

held down the ‘

A

’  button as you 

plugged the panel in. Just unplug the 

panel and plug it back in again and 

the panel will continue to work as 

normal. 

 

If the display shows something different then it might be that your application is using 

the display. Try quitting the application or try the panel on another computer. You 

should also try the solutions in 

The display is always blank

 section. 

 

15.8 The display is always blank 

If your screen is completely blank and you have tried unplugging and plugging the panel 

back in again then check the following: 

 

It might be that your application is using the display. Try quitting the application and 

unplugging the panel and plugging it back in again. 

 

If you’re using an USB hub or repeater, check that there is power going to these. Note, 

your element needs 500mA and so it usually requires that the hub or repeater is 

powered.  Try plugging the panel in directly to the computer without using the hub or 

repeater. 

 

Try plugging the panel in directly to another computer. 

 

Try a different USB cable. 

 

If after trying the above and the display still remains blank, then contact your reseller or 

Tangent Wave. 

 

15.9 My panel keeps saying “Demo panel – resetting in 

X

 sec” 

If you have bought your panel as “new” and you are getting this message then please 

contact Tangent Wave. Your panel thinks it is a “demo” panel and as such it will reset 

every 30 minutes. 

 

 

Содержание element Tk

Страница 1: ...User Manual v1 17 rev2 Important Check www tangentwave co uk for updates Tangent Wave Ltd Crowbush Farm Luton Road Toddington LU5 6HU UK www tangentwave co uk...

Страница 2: ...e il riciclaggio 6 6 About this manual 7 7 What s in the box 7 8 Requirements 7 9 About the Element series of control panels 8 9 1 Drivers 8 9 2 Software 8 9 3 Power and communication 8 10 Positionin...

Страница 3: ...e o The apparatus does not operate normally o The apparatus has been dropped 1 1 CE Declaration of Conformity Tangent Wave Ltd of 4 Crowbush Farm Luton Road Toddington United Kingdom declare that our...

Страница 4: ...htigkeit ausgesetzt o Das Ger t funktioniert nicht normal o Der Apparat wurde fallen gelassen 2 1 CE Konformit tserkl rung Tangent Wave Ltd 4 Crowbush Farm Luton Road Toddington United Kingdom erkl rt...

Страница 5: ...ou l humidit o L appareil ne fonctionne pas normalement o L appareil a t abandonn 3 1 D claration de conformit CE Tangent Wave Ltd de 4 Crowbush Farm Luton Road Toddington United Kingdom d clare que n...

Страница 6: ...o no funciona normalmente o El aparato ha sido abandonado 4 1 Declaraci n ce de conformidad Tangent Wave Ltd de 4 Crowbush Farm Luton Road Toddington Reino Unido declara que nuestros productos Element...

Страница 7: ...a o umidit o L apparecchio non funziona normalmente o L apparato stato abbandonato 5 1 Dichiarazione di conformit CE Tangent Wave Ltd di 4 Crowbush Farm Luton Road Toddington United Kingdom dichiara c...

Страница 8: ...rove our services and products 7 What s in the box Element leaflet Element panel USB cable 2 x Link pins 8 Requirements Any operating system that has a built in USB HID driver Current versions of macO...

Страница 9: ...use to work with your computer 9 2 Software Some applications will work with the panels without any additional software being installed Some applications will require the Tangent Hub support pack whic...

Страница 10: ...ders or repeaters You can use a USB hub to connect multiple panels to your computer The important thing to note is that the hub must be powered and must be able to provide 500mA to each USB port simul...

Страница 11: ...number See the section on updating the firmware for more information on this 14 2 USB state This is the current status of the USB connection This will change and update rapidly when the panel is first...

Страница 12: ...f it does not change then the ball is faulty For the ring should be positive when the ring is turned clockwise and negative if turned anti clockwise If the number is always 1 or 1 or doesn t change th...

Страница 13: ...communicating with the panel Generally problems with communication are related to setting up your software to talk to the panel Refer to your software vendors instructions for doing this Make sure the...

Страница 14: ...y is always blank section 15 8 The display is always blank If your screen is completely blank and you have tried unplugging and plugging the panel back in again then check the following It might be th...

Страница 15: ...e three white balls the ball sits on and the lenses which houses the optical sensor The ring on the trackerball is held in place by magnets in the ring When replacing the ring make sure it locates cor...

Отзывы: