25
5.
OVERALL PERFORMANCE SPECIFICATION
5.1
Insulation Resistance at 1000V DC
The insulation resistance will not be less than 10 megohms between mains input to
frame and all isolated outputs, and all combinations of isolated output to isolated
output.
5.2
Applied Voltage Test
Mains input to frame and all isolated outputs 2kV RMS for 1 minute.
All combinations of isolated output to isolated output.
Isolated output to frame.
1.5kV RMS for 1 minute.
5.3
Accuracy of Instruments
The ammeter plus appropriate current transducer better than + 1.5% of full scale
5.4
Polarity
Zero phase shift.
Mains input - auxiliary voltage output.
Mains input - current output (Common = Neutral).