![TANDBERG ENTRYPOINT Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/tandberg/entrypoint/entrypoint_administrators-manual_816795048.webp)
D 14050.04
10.2007
48
TANDBERG
ENTRYPOINT
USER GUIDE
TANDBERG
ENTRYPOINT
USER GUIDE
Dial Plan Examples
Given the supported net types, H.324m, H.323
and SIP, 9 unique inbound and outbound net
type combinations for both DID and IVR dial
plans can be defined
Some of these combinations will be discussed
in a few examples.
Example 1: Number-plan mapping
Entry details: Enabled:
Check
Name:
H.324m-H.323
Net Type:
H.324m
Prefix:
6789
Suffix:
Service:
Direct Inwards Dialling
Arguments:
Net Type:
H.323
A V Mode:
Auto + fallback to audio
Prefix:
5
Suffix:
Use Remainder:
Yes
Allow Forwarding: No
When dialling the number 67890000 there will be a match with
“0000” as the remaining number. The H.323 number that will be
connected to will be: 50000 (construction: Use remainder
number). When dialling number 67894321 this will match with
“4321” as the remaining number. The H.323 number to call will be:
54321. In this way a range of ISDN numbers can be mapped onto
for instance a range of H.323 numbers.