100
TANDBERG 3000
MXP
&
6000
MXP
REFERENCE GUIDE FOR SYSTEM INTEGRATORS
Configuration-type Commands – xconfiguration / configuration.xml
D 13887.08
MAY 2008
Kiosk
OneClickConnect: <On/Off>
If turned On, you can make a call with a single click on the green call button on the remote control. The system will call the first entry in “My Contacts” in the Phone Book. NOTE:
This functionality will only work in Kiosk Mode. If set to Off: Does not allow for one click connect in Kiosk mode.
Example:
xconfiguration kiosk oneclickconnect: off
LocalLayout
Mode: <Full/2Split/POP/POPwide>
Defines the picture layout to use on the local main monitor. POP and POPWide should only be used on wide screen monitors.
Example:
xconfiguration locallayout mode: full
LocalLayout
Toggle: <PIP/POP>
Defines the behaviour of the Layout button on the remote control.
If set to
POP
the system will toggle through the different LocalLayout modes when pressing the Layout button.
If set to
PIP
, the system will display a PIP when pressing the Layout button.
Example:
xconfiguration locallayout toggle: pip
Logo: <On/Off>
If set to
On
the system will display a company logo will appear in the background of the welcome menu.
NOTE!
The TANDBERG logo will be displayed if no other company logo is uploaded.
Example:
xconfiguration logo: on
LoS
Duration
Exponent: <10..30>
Example:
xconfiguration los duration exponent: 15
The duration of the LoS-pulse can be calcu-
lated from:
Duration =
2
Exponent
bit rate
LoS configurations are relevant
for systems with NET interface
(External Network) only.
LoS
Duration
Offset: <0..65534>
Offset is specified in milliseconds
Example:
xconfiguration los duration offset: 100
LoS
Inhibit: <0..65534>
Specifies the number of seconds to wait before issuing a new LOS pulse if the codec regains and subsequently loses H.221 frame align
-
ment.
Example:
xconfiguration los inhibit: 15
Kiosk