7.
Place the tape drive cover plate on the autoloader’s back panel (see
Figure 1
). Make sure that
the cables aren’t pinched by the cover plate. Insert and tighten the two screws.
4 R
ESUMING
O
PERATION
To resume operation:
1.
If you disconnected the SCSI or FireWire cable, terminator or ESD label, or Ethernet cable
from the autoloader, reconnect them.
2.
Reconnect the power cord and power on the autoloader, as described in the
Tandberg
StorageLoader VXA Product Manual
. Calibration of the new tape drive occurs automatically
during power on.
The autoloader is now ready to resume operation. For the SCSI autoloader, the new tape drive
automatically assumes the SCSI ID of the old tape drive.
You may want to perform a few cartridge load and unload operations from the front panel to
ensure that the autoloader and the newly installed tape drive are communicating correctly (see
instructions below). You may also want to back up several megabytes of data with the new tape
drive and perform a comparison check on the backed-up data. This determines whether the
software and tape drive are communicating properly.
L
OADING
AND
U
NLOADING
C
ARTRIDGES
Before you can load a cartridge into the tape drive, the autoloader must already contain a
cartridge or you must insert a cartridge through the cartridge access port. See the
Product
Manual
for instructions.
To load a cartridge into the tape drive:
1.
At the Home screen, press
,
,
, or
to access the main menus.
2.
If necessary, enter the operator panel password (see the
Product Manual
for more
information).
3.
Press
or
until the Command menu appears:
4.
Press
to see the menu selections.
5.
Press
or
until the following screen appears:
S e l e c t
a
C o m m a n d
L o a d
D r i v e