RDX QuikStation 4 and 8 Product Manual
8 - System Maintenance
1021970 Rev. D
©2016-18 Tandberg Data GmbH
101
The Import Configuration dialog window opens.
2.
Select the network settings you want to import.
By default, all configuration settings are selected.
3.
Click the plus (
+
) icon to select the RDX QuikStation configuration file.
4.
Click
Import
.
The system reboots. This process takes three minutes. When the reboot is complete, the
Remote Management Console interface is active again. You do not have to sign in again
to access the Console.
If the imported file contains different network settings than are currently active, you
may have to reopen the browser with the updated RDX QuikStation IP address. Refer to
“Obtain the IP Address” on page 17
to determine the current IP address.
Manually Update RDX QuikStation Firmware
If the
Check firmware update automatically
), when you sign in as an administrator, the RDX QuikStation detects
the firmware version. If your system is not running the most current version, the RDX
QuikStation prompts you to update the firmware. If you choose to update, the system
automatically installs the new firmware version.
Follow these instructions if you need to manually update the firmware file to your system.
CAUTION:
Before you update the firmware, make sure there are no active hosts that are
currently communicating with the iSCSI targets.
To manually update the RDX QuikStation firmware:
1.
From the Remote Management Console main menu, select
System Maintenance > Update
Firmware
.