RDX QuikStation 4 and 8 Product Manual
4 - System Configuration
1021970 Rev. D
©2016-18 Tandberg Data GmbH
55
Options for RDX QuikStation
The Options dialog window is divided into four tabs:
System
,
Removable Disk
,
Automation
, and
Diagnostics
. Refer to the table below for information about each tab.
To access the Options dialog, from the Remote Management Console main menu, select
System Settings > Options
.
Tab
Option
Description
System
Check firmware update
automatically
Recommended. Provides notifications about new firmware
releases on Internet-accessible networks.
Allow multiple host
connections
Allows multiple iSCSI connections to drive targets from
multiple hosts in cluster environments when hosts can
manage drive access. To avoid data corruption, multiple iSCSI
initiator sessions should only be enabled when operating in a
cluster aware filesystem. This option also supports MPIO for a
single host by allowing multiple connections from the host.
Removable Disk
Unsafe Eject
Allows you to enable the “Unsafe Eject” mode for RDX media
that have an established host connection (see
Removable Disk Options” on page 56
Automation
Auto-Insert Options
Allows you to enable the “Auto-Insert” mode tape automation
devices. If set, then cartridges physically inserted in the
QuikStation docks will be logically placed in an empty tape
library rather than in the Import/Export slot (see
Auto-Insert Option” on page 57.
Diagnostics
Log Level
Allows you to change the log level from Normal to Detail or
Extend. Tandberg Data recommends you only change the log
level if you are instructed to do so by Tandberg Data Technical
Support.
NOTE: If you change the log level, the system will default to
“normal” once the Management Console browser
session is closed.
Remote Access
Allows you to control remote access to the RDX QuikStation via
SSH (Secure Shell) for Technical Support. This feature is
enabled by default.