Site Requirements
exhausted through vents at the back of the library. To ensure that the library
is adequately ventilated:
• Place the library on a hard, level surface, or in a standard 19-inch rack.
• If the library will be placed in a rack, the rack must be open or ventilated
so that the air temperature behind the library at the air outlets is less than
104°F (40°C).
• Verify that no cables obstruct the vents at the back of the library (see
and
).
• Verify that nothing obstructs the vents at the lower edge of the front
bezel.
• Allow at least 5 inches (12.7 cm) of space behind the library or rack.
• Do not install the library near a heater or radiator which could warm the
air drawn into the library.