FD-M
English
Page 47
Name of CVs /
Registers
CV-
no.
Reg.
no.
Input value
(Default)
Remarks and Tips
Assignment of the function keys
to the outputs
F0 forward on 33
08
0 ... 31 (1)
F0 backward on 34
09
0 ... 31 (2)
Numerical value
*
F1
35
10
0 ... 31 (4)
Assigned output:
F2
36
11
0 ... 31 (8)
AUX1
1
F3
37
12
0 ... 31 (16) AUX2
2
F4
38
13
0 ... 31 (0)
AUX3
4
...
...
...
0 ... 31 (0)
AUX4
8
F12
46
21
0 ... 31 (0)
X7
16
Factory settings: AUX1 to be switched with F0, switched on at forward motion.
AUX2 to be switched with F0, switched on at backward motion. AUX3 to be
switched with F1. AUX4 to be switched with F2. X7 to be switched with F3.
Example: AUX2 to be switched with F5
à
CV#39 = 2
Example: AUX1 and AUX3 to be switched with F6
à
CV#40 = 5 (= 1+4)
Dimming of the outputs:
AUX1
49
22
1 ... 64 (64)
AUX2
50
23
1 ... 64 (64)
AUX3
51
24
1 ... 64 (64)
AUX4
52
25
1 ... 64 (64)
= Reducing the voltage
applied to the output A.
value of "1" corresponds to
the minimum, "64" to the
maximum voltage.
Dependant on the direction of motion
Numerical value
*
of the outputs and function keys
independent of direction
0
AUX1 / F1
53
26
0 ... 63 (0)
F off at forward motion
1
AUX2 / F2
54
27
0 ... 63 (0)
F off at backward motion
2
AUX3 / F3
55
28
0 ... 63 (0)
AUX off at forward motion 4
AUX4 / F4
56
29
0 ... 63 (0)
AUX off at backward motion 8
Shunting light AUX at F3 16
Shunting light AUX at F4 32