Environment

For use in closed rooms 

Ambient temperature during 
operation

0 ~ + 30 °C

Permissible relative humidity 
during operation

10 ~ 85% (non-condensing)

Ambient temperature during 
storage

- 10 ~ + 40 °C

Permissible relative humidity 
during storage

10 ~ 85% (non-condensing)  

Other features

Dimensions (approx.)

Circuit board:  48 x 52 mm
Ready device including housing:  70 x 60 x 25 mm

Weight (approx.)

Assembled board (ready-made module): 22 g
Ready device including housing: 39 g

Technical data | 15

Содержание KSM-4

Страница 1: ...KSM 4 Loop Module for digital model railroad layouts Manual Item nos 49 01146 49 01147 tams elektronik n n n...

Страница 2: ...translation Copies reproductions and alterations in any form require the written permission of Tams Elektronik GmbH We reserve the right to make technical changes Printing the manual The formatting i...

Страница 3: ...3 Procedure 7 2 4 Designing a layout with the KSM 4 8 2 5 Use with a turntable 8 3 Connections KSM 4 9 3 1 Dividing the loop into sections 9 3 2 Connections 10 4 Operation 11 5 Checklist for troubles...

Страница 4: ...t and tested circuit board KSM 4 item no 49 01146 01 or 1 loop module KSM 4 in housing item no 49 01147 01 2 push buttons 1 2 Accessories Connection cables The use of stranded wire is recommended for...

Страница 5: ...th extra low voltage as specified in the technical data Use only tested and approved transformers Only plug the mains plugs of transformers into properly installed and fused earthed sockets When makin...

Страница 6: ...doing so adapting the polarity within the terminal loop depending on the position of points The points can be switched in differant ways automatically when a train is leaving the terminal loop by mea...

Страница 7: ...ince the last train has left the polarity within the terminal loop is already set correctly Phase 2 Train leaving the terminal loop As soon as a vehicle a locomotive or a carriage with current consume...

Страница 8: ...ints simultaneously This allows branching rails or installing a shadow station within in terminal loop for example The maximum current of all vehicles in the loop is 3 A including motor current of the...

Страница 9: ...he inner section of the loop Isolate at the transition to the points both rails at the transition to the terminal loop s inside the outer rail in both cases The transition zones should be about half a...

Страница 10: ...ntion to assigning both rail connections exactly as shown in the figure 3 4 Transition zones outer rail in both cases 5 6 Inner section of the loop 5 outer rail 6 inner rail 7 8 Push button 1 9 10 Pus...

Страница 11: ...the desired address at you digital central unit and perform a switching command for this address 3 The programming mode is terminated automatically Both LEDs flash together several times and remain s...

Страница 12: ...ints W1 and W3 have been connected the wrong way For that reason the polarity within the terminal loop does not correspond to the actual position of points Interchange the connections to the points W1...

Страница 13: ...ty or guarantee claim we are entitled to charge you the costs of the repair and the costs of the return shipment We charge a maximum of 50 of the new price for the repair according to our valid price...

Страница 14: ...e direct connection of coil driven or motor run points Maximum current 1 A Switching time 100 ms to 5 sec adjustable Inputs 2 connections for push buttons Electrical characteristics Voltage supply via...

Страница 15: ...ion 10 85 non condensing Ambient temperature during storage 10 40 C Permissible relative humidity during storage 10 85 non condensing Other features Dimensions approx Circuit board 48 x 52 mm Ready de...

Страница 16: ...f the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and th...

Страница 17: ...product is subject to the requirements of the EU Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE i e the manufacturer distributor or seller of the product must contribute to th...

Страница 18: ...KSM 4 tams elektronik 18...

Страница 19: ...tams elektronik KSM 4 19...

Страница 20: ...ation and Tips n n http www tams online de n n n n Warranty and Service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail modellba...

Отзывы: