6.Technical specifications
Data format
DCC and Motorola
Feedback log
RailCom
Supply voltage
12-24 Volt digital voltage
Current consumption
(without connected loads)
approx. 10 mA
Max. current of the function outputs 100 mA each
Max. total current
300 mA
Protected to
IP 00
Ambient temperature in use
0 - + 60° C
Ambient temperature in storage
-10 - + 80° C
Comparative humidity allowed
max. 85 %
Dimensions
approx. 12,5 x 9,5 x 3,3 mm
Weight
approx. 0,6 g
7. Mounting the FD-R
Basic
Follow the connection diagram fig. 1.
Open the vehicle´s housing. Locate the position for the module.
Solder the connections from the rail current collectors at the points X4
and X5. Assign the connections as follows:
X4: left rail current collector (seen in direction of motion)
X5: right rail current collector (seen in direction of motion)
Tip:
It is not possible to send a confirmation signal to the central unit in
DCC format when there is not sufficient current consumption. Therefore
you should connect at least one accessory with a current consumption
of max. 100 mA before starting to program the module if using it as a
function decoder. In case you use the module as a RailCom-transmitter
only, this is not necessary.