tams elektronik FCS-3 Скачать руководство пользователя страница 12

English

FCS-3

Seite 28

!

Reed contacts

Depending on their version reed contacts fulfill the task of a
closer or a change-over switch. They respond to a magentic
field, thus making possible contactless switching operations.
They consist of a glass bulb filled with a protective gas.
Sealed in the glass bulb are two or three reeds made of a
magnetic material. When bending the legs the glass bulb they
can be easily damaged through mechanical strain.

Mounting the FCS-3

Preparation

Open the housing of the vehicle. Locate the position for the module.

Disconnect all connections from the accumulator batteries, the motor and
the mounted reed contact except for the lead-in wire to the charging
contact.  Follow the connection diagram fig. 2 (page II in the centre of this

handbook) and the special features of the addional components.
In many vehicles the resistor R7 shown in the connection diagram is
mounted into the lead-in wire to the motor. The resistor has to be
connected to the plus pole of the accumulator battery if not yet

mounted that way. If there is no resistor, R7 is not applicable.

Connection to the supply voltage

Connect the connecting point X2 to the plus pole of the  accumulator
battery and the minus pole of the accumulator battery to the existing
switch S of the vehicle. Connect the second pole of the switch to the

connecting point X1.

Caution:

The module should not be connected the wrong way round. Otherwise
it will be destroyed when put into operation.

Connection of the existing reed contact

The existing reed contact has three connecting points, one at side A

and two at side B. Connect the connecting point at side A to the
connecting point X2 and the plus pole of the accumulator battery.

Содержание FCS-3

Страница 1: ...r Faller Car System n n Bus module compatible to the Faller Car System n n Anleitung Module pour autobus du Faller Car System n Manual n Mode d emploi Busmodule voor het Faller Car System n Handleidi...

Страница 2: ...any means electronic or mechanical including photocopying without prior permission in writing from Tams Elektronik GmbH Subject to technical modification 07 2005 Tams Elektronik GmbH Tout droits r ser...

Страница 3: ...ranty 32 Connections Fig 2 II Page II in the centre of this handbook is removeable How to use this manual If you have no specialist technical training this manual gives step by step instructions for s...

Страница 4: ...manual are mandatory for the user Any other use is inappropriate and invalidates any guarantees Safety instructions Mechanical hazards Cut wires can have sharp ends and can cause serious injuries Wat...

Страница 5: ...ammable material with a hot soldering iron can cause fire which can result in injury or death through burns or suffocation Connect your soldering iron or soldering station only when actually needed Al...

Страница 6: ...small children In schools training centres clubs and workshops assembly must be supervised by qualified personnel In industrial institutions health and safety regulations applying to electronic work m...

Страница 7: ...the software Front lighting Additional to the six in and outputs controlled by the software there can be connected up to two additional white LEDs for the front lighting to the additional output Thes...

Страница 8: ...The reed contact that is in the vehicle and the additional reed contact should be connected to the module The module then influences the motor After a stop it starts gently When crossing the stop wit...

Страница 9: ...ontact one manual Required tools and materials Make sure you have the following tools and materials ready for use an electronic soldering iron max 30 Watt with a fine tip a soldering iron stand a tip...

Страница 10: ...soldering eyes Apply the soldering tip to the soldering spot in such a way that the wire and the soldering eye are heated at the same time Simultaneously add solder not too much As soon as the solder...

Страница 11: ...low signals into stronger ones They have three contacts As they are polarized they have to be mounted in a certain direction Die BC Types have a housing in form of a half cylinder SOT housing The thre...

Страница 12: ...of this handbook and the special features of the addional components In many vehicles the resistor R7 shown in the connection diagram is mounted into the lead in wire to the motor The resistor has to...

Страница 13: ...e vehicle Connect the enclosed reed contact to the connecting points X3 and X9 Caution Reed contacts are sensitive to stress Therfore be careful when bending the legs in oder not to destroy the glass...

Страница 14: ...point X3 Caution The LEDs for the front light which are connected to the voltage output must be operated via series resistors Otherwise the connected LEDs are damaged and the circuit may not work as i...

Страница 15: ...e wrong connecting point at side B of the existing reed contact was used Check the connection The vehicle drives backwards Possible cause The connections of the motor are connected reverse Check the c...

Страница 16: ...ase price The following invalidate the warranty using an unsuitable soldering iron solder containing liquid acids or similar if damage is caused by not following the instructions in this manual or the...

Страница 17: ...English FCS 3 Page II 1 Fig 2 Connections...

Страница 18: ...dary reed contact External Components D2 Additional Diode 1N4148 G1 G2 Existing chargable batterries LED1 LED2 White LEDs for front lighthing LED3 LED4 Yellow LEDs fort he right indicator LED5 LED6 Re...

Страница 19: ...ctuele informatie en tips n http www tams online de n n n n Garantie und Service Warranty and service n Garantie et service Garantie en service n n Tams Elektronik GmbH n Rupsteinstra e 10 D 30625 Han...

Отзывы: