tams
elektronik
English
BiDiBooster
Function
Value for
CV#7
Settings / Remarks
Autostarting time
after a short circuit
Default value:
4 sec.
34
4 sec.
35
5 sec.
36
6 sec.
...
7 ... 9 sec.
40
10 sec.
Max. track current
(interrupting
current)
Default value: 3 A
42
2 A
43
3 A
44
4 A
RailCom. Default
value: active
51
active
52
inactive
Determining the
interface
53
BiDiB-booster port
54
DCC-booster port
55
Reception of the booster signals via
the DCC-booster port and
transmission via the RJ 45-booster
port
Switching off with a
DCC points
switching command
Default value:
inactive
71
active
72
inactive
73
Change over into the progr. mode.
When within 30 sec. a DCC points switching
command is set, the BiDiBooster takes over the
corresponding points address to release the
switching off funtion.
Condition: Switching off function = "active".