background image

1. Cut a hole in the ceiling under where the HV1450 will be installed.  Suggested methods for making
the proper sized hole in the ceiling are; cut a pilot hole under where the fan will be installed. Cut toward
the edge to find the joist pattern and layout the fan opening on the ceiling; OR the four corners of the
opening from the attic side and draw a line between each of the four corners to layout the fan opening;
OR use a stud finder to locate the joists, cut a template from the fan packaging material and use the
template to layout the fan opening.The dimensions of the hole should be
no greater than 22-1/2” x14-1/2”. This will allow for the grille to cover the
exposed sheetrock edges.

2.  The  fan  housing  will  fit  either  16”  or  24”  on-center  framing.  Cut  two
pieces of 2x stock (2x6 or 2x8 etc.) of the same dimension as the exist-
ing joists. Add these pieces of framing to form a box between the joists.

3. Install foam weatherstrip material (not supplied) on the top of the joists
and added framing. Caulk the joist between the ceiling and the 2x stock.
Some types of ceilings are spaced away from the joists. Any gap between
the 2x’s and the ceiling should be sealed prior to final installation. Use a
low expansion spray foam sealant (not supplied).

4.  Insert  the  threaded  end  of  the  hex  standoffs  through  the  hole  in  the
housing. From the backside of the housing secure each standoff with a
locknut. Place the damper on the housing with the label side facing the
attic space. Pass the standoffs through the holes in the damper. Secure
the  damper  in  place  with  a  flat  washer  and  phillips  head  screw.  The
damper should move freely about the standoffs.

5. Set the HV1450 on the gasket with the damper facing into the attic. The
housing will fit the framing with the mounting flanges over lapping the joists.

6. If desired, secure the HV1450 to the top of the joists using wood screws
(not  provided).  When  fastening  the  mounting  flange  to  the  joists,  care
should be taken that all screws are tightened evenly. 

7. Wire the HV1450 as shown in the wiring diagram. It is recommended
wiring of the HV1450 be done by licensed electrician.

8. Install grille (6 screws included) on the ceiling below the fan. 

Installation 

Tools and supplies needed (Not Included): 

You will need the following items: two pieces of 2x stock to match your existing framing,

a saw to cut the hole in the ceiling, a hammer or screw gun to attach the blocking to the existing joists, a Phillips head screw driver to attach the
grille, weather strip material and low expansion spray foam sealant.

TROUBLE SHOOTING:

The most common problem with the HV1450 is

caused  by  incorrect  wiring.  Before  you  check  anything  else  make  sure
WHITE wire in HV1450 is connected to 115 VAC line neutral: BLACK wire
is connected to a switch that will make it hot when the switch is closed. 

CARE:

All the motors are permanently sealed and do not require oiling. To

keep dirt, dust and debris from fan, we recommend you periodically remove
the grille from within the living space and dust the fan blades. Please remem-
ber to make sure that the fan is OFF before dusting the fan blades

SPECIFICATIONS: 

Voltage . . .115VAC 60Hz
Power . . . . . . . .78 Watts
Airflow  . . . . .1450 CFM       

Weight   . . . . . . . . .13 Lbs.
Rough Opening   

 . . . . . . . .14 1/2” x 22 1/2” 

Grille Outside Dimensions

 . . . . . . . .15 3/4” x 25 3/4”

Grille Color  . . . . . . . .White

WIRING:

There are two

wires in the electrical box plus
the ground: WHITE and
BLACK. 

• Connect the White wire to

Line Neutral

• Connect the BLACK wire to

a Switched Hot Feed or the
output leg of your switch.

• Connect the ground wire to

the screw in the 
electrical box

320 Main Street • Buzzards Bay, Ma 02532

508-759-4660 / 800-222-5932 / Fax 508-759-6001

LIMITED  WARRANTY

IF,  WITHIN THE  PERIOD  OF  90  DAYS  FROM  DATE  OF  PURCHASE THE  HV1450  (THE  PRODUCT)  IS  DEFECTIVE  OR  MAL-

FUNCTIONS IN NORMAL HOME USE, TAMARACK WILL REPAIR OR REPLACE THE HV1450 AT ITS DISCRETION WITHOUT CHARGE FOR LABOR OR MATE-
RIALS. CUSTOMER IS RESPONSIBLE FOR SHIPPING CHARGES. NOTE: SOME STATE CODES REQUIRE FANS  TO BE HARD WIRED. HARDWIRING THE
HV1450 WILL NOT VOID WARRANTY PROVIDING THE WIRING IS PERFORMED BY A LICENSED ELECTRICIAN. 

CONDITIONS,  EXCLUSIONS,  AND  LIMITATIONS

-THIS  WARRANTY  IS  SUBJECT TO THE  FOLLOWING  CONDITIONS,  EXCLUSIONS

AND  LIMITATIONS.  THIS  WARRANTY  DOES  NOT  COVER  PROBLEMS  RESULTING  FROM  INSTALLATION,  OPERATION  OR    MAINTENANCE  THAT  HAS
BEEN UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS. THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM
DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT (FURNACES, SOLARIA, ETC.) ; FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY PERSONS
OTHER THAN TAMARACK.;  FROM ABUSE, ACCIDENTAL OR SHIPPING DAMAGE, ACTS OF GOD. THIS WARRANTY DOES NOT APPLY TO THE PRODUCT
USED OUTSIDE THE UNITED STATES, ITS TERRITORIAL POSSESSIONS AND CANADA. EXCEPT AS SET FORTH ABOVE, NO EXPRESS OR IMPLIED WAR-
RANTY  IS  GIVEN  OR AUTHORIZED  BY TAMARACK. AND ALL  OTHER  SUCH  WARRANTIES ARE  EXPRESSLY  DISCLAIMED. ANY  WARRANTY  OR  MER-
CHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER. MOREOVER, ANY LIABILITY OF
TAMARACK FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT OF THE PRODUCT. IN NO EVENT SHALL TAMARACK BE LIABLE FOR ANY
INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES, IRRESPECTIVE OF THE CAUSE THEREOF, OCCUR-
RING EITHER DURING OR AFTER THE WARRANTY PERIOD. INCLUDING WITHOUT LIMITATION ANY DAMAGE TO ANY PART OF A BUILDING OR ITS CON-
TENTS. NOTE: SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. 

PROOF OF PURCHASE REQUIRED.

P/N HVM 1450.6