Select Fan Location
When selecting a location to install the Dragon fan, take into consideration the
application of the product, the locations of fresh air intakes, and sound generated
by the Dragon unit. If ductwork is to be used, consider the path of the ducting
material.
The fan should be located a minimum of 6 feet horizontally and 8 feet vertically
from any fresh air intakes for HVAC systems, heat recovery systems, etc. to
prevent exhaust air streams from being re-introduced into the occupied space.
Doors or windows that are frequently opened during pleasant seasons may also
be considered fresh air intakes so keep this in mind when selecting the location
of the Dragon.
Locate Mounting and Through Holes
Once the location on the exterior wall where the fan is to be mounted has been
selected, mark all screw and hole locations utilizing the included template. Cut
the holes through the wall for the duct connection and for the electrical conduit.
Measure the thickness of the wall and the length of the duct flange that is part
of the Dragon fan. Cut a length of duct (not supplied) so that once connected to
the duct flange, it will eliminate air leakage into the wall cavity. Attach grille or fan
guard (not supplied) to prevent objects from entering ductwork and fan.
If mounting the fan on a masonry wall, drill four holes and insert wall anchors. If
mounting to wooden structure, you will utilize wood screws to secure the Dragon
to the wall. If the fan is to be mounted on a wall surface which is not flush such
as lapped siding, a mounting plate to provide for a flush fit needs to be made.
Mount the Fan
Insert electrical supply through the wall. Attach the duct extension to the Dragon
making sure that the connection is secure. Apply a generous amount of exterior
silicone caulk (not supplied) to backplate of the fan to ensure an airtight/
waterproof connection between the fan and the wall surface. If a mounting frame
is used in conjunction with lapped siding, be certain to apply a generous amount
of caulk between the frame and the wall as well as the fan backplate and the
frame. Mount the fan to the wall.
Note: Be certain to make an airtight seal around all interior wall penetra-
tions before attaching duct work.
Electrical Connection
All Dragon series fans operate from a standard 120V 60Hz A.C. electrical supply.
All wiring must be carried out in accordance with applicable state and local
2
Содержание Dragon 100