(a)
(b)
Fig. 2. FlySense AoA should be mounted parallel to the main axes of the airplane.
1.2 Connection
FlySense AoA is powered by:
The external DSUB25 connector. The pin-out configuration is as follows:
PIN CONNECTION
1
Main Power 12V to 30V (+ve) (white wire factory connected)
4
(reserved)
5
(reserved)
7
(reserved)
8
(reserved)
9
temperature probe blue or yellow(factory connected)
10
GND
11
(reserved)
12
(reserved)
13
GND
15
Autopilot/Transponder extended squitter. RS232(9600,8/N/1) 3.3V, NMEA 0183.
21
temperature probe black (factory connected)
22
temperature probe red (factory connected)
24
(reserved)
25
Main Power (0V) (black wire factory connected)
The instrument should be connected through a fused connector for power; such connector may be
the cigarette lighter plug of the aircraft. The instrument has reverse polarity protection, however
always make sure to connect with the proper polarity:
The red/white cable connects to the positive (+ 12V to +30V)
The black cable connects to the negative (0V)
4