Specification 

Operating principle 

Laser scattering 

 

 

Yes 

 

Accuracy and range 

Temperature accuracy 

 

± 0,2 °C (conditions 0 °C to +50 °C)

Temperature range 

 

 

-20 °C to +60 °C 

Humidity accuracy   

 

± 2% (conditions 10-90% RH)

Humidity range 

 

 

0% to 100% non-condensing 

Particulate matters ranges 

 

PM

1.0

, PM

2.5

, PM

10

 

 

Connectivity 

Network 

 

 

 

LoRaWAN 

Frequency bands 

 

 

868 MHz 

Provisioning   

 

 

Over the air & personalization 

 

Size 

Size   

 

 

 

111 x 77 x 26 mm 

Weight  

 

 

 

75g 

 

Security 

Algorithms 

 

 

 

AES-128

 

Hardware 

 

 

 

Cryptographic co-processor 

Features 

 

 

 

Secure boot 

 

 

 

 

 

Secure firmware upgrade 

Hardware based ultra secure key storage

 

 

Power 

DC power 

 

 

 

5-24 V

 

AC power 

 

 

 

Via USB charger (not included) 

 

Содержание OY1700

Страница 1: ...OY1700 LoRaWAN Air quality PM sensor User manual Version 0 1 September 2019...

Страница 2: ...nfiguration 8 5 2 Sensor states and state check 8 5 2 1 Re join functionality 10 6 Specification 11 7 Security 13 8 Protocol 13 8 1 LoRaWAN standard commands 13 8 2 Unsolicited uplink status commands...

Страница 3: ...rtify that the design and manufacturing of this product WIRELESS CO2 SENSOR FUNK CO2 SENSOR TR DL S CO2 SENSOR TR D S CO2 SENSOR DRAADLOZE CO2 SENSOR OY1210 EU868 conforms to the following directives...

Страница 4: ...collection point designated for the recycling of electrical and electronic appliances Separate collection and recycling of your waste at the time of disposal will contribute to conserving natural res...

Страница 5: ...to measure PM10 PM2 5 PM1 0 temperature and humidity in indoor environments The sensor is intended for indoor climate control and monitoring indoor air quality It is optimized for reliable and secure...

Страница 6: ...board and the top cover Remove the top cover by pressing it upwards and outwards The electronics are removed by releasing the plastic latch on the top The bottom piece is mounted on the wall with the...

Страница 7: ...C The cable can be routed through the cable canal or through the electronic board for junction box mount The sensor starts and flashes 8 times during the boot up sequence and starts the join sequence...

Страница 8: ...onfigured with device unique DevEUI and AppKey The DevEUI is printed on device box and the AppKey is distributed by the sales team The device is default configured for OTA provisioning Contact the Tal...

Страница 9: ...in is indicated with a 2 sec long flash To check the device state press the button and hold it pressed until the red LED starts flashing after 0 5s State Description LED response Initial Low power sta...

Страница 10: ...es temperature and humidity periodically and sends measurement reports toward a LoRAWAN network 1 long flash 2 sec 5 2 1 Re join functionality The device supervises its connectivity to the network by...

Страница 11: ...nditions 10 90 RH Humidity range 0 to 100 non condensing Particulate matters ranges PM1 0 PM2 5 PM10 Connectivity Network LoRaWAN Frequency bands 868 MHz Provisioning Over the air personalization Size...

Страница 12: ...rsion 0 1 12 Configuration Measurement intervals 15 minutes configurable over the air Transmission intervals 15 minutes configurable over the air Unique App EUI available upon request Enclosure IP30 C...

Страница 13: ...Uplink query response Note 0x denotation means hexadecimal encoded 8 1 LoRaWAN standard commands All standard LoRaWAN v 1 0 2 are supported Please refer to the LoRaWAN standard for the protocol defin...

Страница 14: ...load Measurement value see chap 8 3 2 Size 5 Bytes 8 3 2 Measurement value The measurement value for each measurement Byte 0 Temperature bit 11 bit 4 Byte 1 Relative humidity bit 11 bit4 Byte 2 bit 7...

Страница 15: ...ided with 10 to get it in RH 8 3 2 3 Particulate Matter PM conversion The Particulate Matter of different sizes PM10 PM2 5 and PM1 0 are measurement in parts per million ppm 1 x 10 6 is transmitted us...

Страница 16: ...e sent from the server application Contact your LoRaWAN network provider for in band application API All downlink application communication is done on LoRaWAN port 1 Downlink command network device Fi...

Страница 17: ...CPU temperature Uint16 Big endian 50C 0 01C LSB 50 125 C Query No Temperature from CPU sensor with 50 C offset Approximately 5 C accuracy 1 0x20 Status Uint8 Bitfield Query Yes Should be 0 otherwise...

Страница 18: ...t 1 01230005 Set measurement interval to 15 minutes Port 1 0123000F 8 4 2 Reset device The device can be remotely reset and forced into Joining state All settings are back to factory default Example R...