WEBS-PM
–
Pedestal Mount
Emergency Phone Station with WEBS
®
Installation Instructions
Copyright 2014 Talk-A-Phone Co.
• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.
Rev. 4/7/2014
I. Introduction
WEBS-PM
Pedestal Mount Emergency Phone Station with WEBS
®
is designed to mount to concrete
foundation using anchor bolts.
II.
Contents
Before beginning installation, make sure you have all the included components. Each Pedestal consists
of three packages. Package #1 is the labeled
WEBS-PM-KIT
. Package #2 is labeled
ETP-PM PARTS
.
Package #3 contains the Pedestal itself.
WEBS-PM-KIT
Qty.
Part Number
Description
1
68642
2-Channel Amplifier
1
86396
Power Supply (12VDC, 5A)
2
83075
Loudspeaker
ETP-PM PARTS
Qty.
Part Number
Description
4
42838
J-Bolts
8
42839
3/4"-10 Hex Nut
8
42840
3/4" Washer
3
42867
10-24 x 1/2" Tamper Resistant Screws
2
42843
6-32 Hex Nut
1
68590
LED Panel Light (12-24VAC/DC, 120VAC)
1
67478
Polycarbonate Cover for LED Panel Light
1
24717
Pedestal Mount Aluminum Template
III. Installation
1. Electrical and telephone line conduits should be run through the foundation and into the center 4"
diameter hole of the Pedestal.
NOTE:
To insure proper grounding of all electrical components, the tower mount should be effectively earth grounded
from the grounding stud (located across from the lower access panel) with 6 AWG or better insulated, stranded copper
wire to the metallic power service raceway (conduit) or an 8 foot or longer corrosion-resistant ground spike. It is the
installer's obligation to ensure compliance with all national, regional, and local regulations
.
2. Pour the foundation at least 2-feet in diameter and 3-feet deep according to your local code and frost
line.
3.
Install the four (4) 3/4”
-
10 x 24” long anchor bolts below grade
with five inches
(5”)
projecting
above grade
. Use the template provided to properly position the bolts within the concrete
foundation.